background image

www.PumpAgents.com

ELECTRICAL CONNECTIONS - Select a location for
the switch and instruction plate, making sure wire leads
from both the toilet and power source can be routed to
the switch. Ensure the panel where installing switch is no
more than 1" thick. Drill a 5/8" mounting hole and install
switch and instruction plate. Use stranded copper wire of
the correct size (determined from the electrical specifi-
cations chart) to connect one side of the switch to the
positive power source. An appropriate size fuse or equiv-
alent circuit breaker (determined from electrical specifi-
cations chart) must be installed in the positive power
lead within seven inches of the power source. Connect
the other side of the switch to the orange (positive) motor
lead. Connect the black (negative) motor lead to the
negative side of the battery or grounded buss bar.

NOTICE: Correct motor polarity (orange to positive,
black to negative) is important. Reverse polarity can
damage motor and void warranty. Full voltage at the
motor is required to properly operate the Electric Toilet.
The toilet must be wired in a circuit independent of all
other accessories.

ELECTRICAL SPECIFICATIONS

AMP

FUSE

WIRE SIZE PER FEET OF RUN*

VOLTAGE

DRAW

SIZE

0'-10'

10'-15'

15'-25'

25'-40'

40'-60'

12 Vdc 

16

25

#12

#10

#10

#8

#6

24 Vdc

8

15

#16

#14

#12

#10

#10

* Length of run is total distance from power source to product and back to ground.

OPERATING INSTRUCTIONS

Make sure inlet and outlet seacocks are all open; push button
to operate. Operate until bowl is completely flushed and
discharge pump has scavenged water from bottom of bowl.

The Jabsco electric marine toilet will provide years of trou-
blefree service if properly used. It will handle waste and toi-
let tissue. It will NOT handle rags, sanitary napkins or hard
solid objects.

If bowl does not pump out and begins to fill, partially close
inlet valve until bowl is cleared and completely pumped
out. Then operate for a few seconds with both valves open
to clear entire toilet and discharge system. For maximum
safety, when toilet is not in use or vessel is unattended,
close both the inlet and discharge seacocks.

To drain for winter lay-up, close inlet valve and operate for
a few seconds until all water is pumped out.

After long periods of non-use, toilet and pump may dry out.
To ease initial start-up, put about one quart of water in bowl
and let stand awhile before initial use.

DISASSEMBLY

Disconnect pumping inlet and discharge hoses. Remove
four screws, Key No. 25, pull out complete motor, pump
and macerator assembly. If assembly does not slide out

easily, push forward and pull back sharply several times to
free macerator housing from base.

Remove discharge port, Key No. 12, and joker valve.
Unscrew chopper plate, Key No. 14, by turning counter-
clockwise, facing plate. Prevent shaft from turning by plac-
ing screwdriver in discharge port and locking centrifugal
impeller blade. Remove macerator housing. Loosen
impeller set screw and slide impeller off motor shaft.

Remove four flathead screws and two washers, Key Nos.
20, 21, & 22. Remove the plastic wearplate, Key No. 23,
with sealing sleeve, Key No. 19, and gasket, Key No. 26.
Slide pump assembly off motor shaft. Replace all worn or
damaged parts, clean remaining parts.

ASSEMBLY

Press seal into body with lip facing impeller; be careful
not to cock seal in bore. Install pump body on motor and
position on register. Lubricate impeller bore with pump
grease and install impeller. Position the gasket against
the body and install the wearplate ensuring the two plas-
tic sealing washers are under the heads of the top and
bottom screws. NOTE: The current plastic wearplate
supercedes the earlier brass wearplate and with it the
stainless steel wearplate is no longer used. Slide the
rubber sealing sleeve on the motor shaft and push it into
its recess in the wearplate. Relocate centrifugal impeller
on shaft, about 1/8" from the wearplate, and tighten set
screw. Place macerator housing over shaft and centrifu-
gal impeller, put lock washer on end of shaft and screw
chopper plate on shaft and tighten. Install O-ring in O-
ring groove in wearplate surface, a little grease will help
hold in place, make sure inside body surfaces are clean,
line up slot in base with key on macerator housing, slide
pump assembly into base and tighten with the four
screws. Turn motor on for one or two seconds to be sure
centrifugal impeller is free.

WARNING

!

Flood hazard.  Close inlet and outlet 
seacocks prior to disassembling toilet.  
Failure to do so can result in flooding 
which can cause loss of property and life.

MOUNTING

BRACKET

VENT TO

ATMOSPHERE

ELECTRICAL

CONNECTIONS

TO VENTED

LOOP

VIEW A

37068-0000

SOLENOID

TO

NEGATIVE

TO

POSITIVE

TO

NEGATIVE

PUSH BUTTON

SWITCH

VENTED

LOOP

VIEW A

DISCHARGE TO
HOLDING TANK

INLET

WATER

LINE

PumpAgents.com - buy pumps and parts online

Summary of Contents for 37010 Series

Page 1: ...rictions For above waterline installations a check valve may have to be installed in the flush water intake line to ensure rapid pump priming To retain water in bowl make a loop in the discharge line about 8 inches above base of bowl Do not connect the toilet to the vessels potable water for its source of supply To do so can result in contamination of potable water supply If fresh water is preferr...

Page 2: ...t up put about one quart of water in bowl and let stand awhile before initial use DISASSEMBLY Disconnect pumping inlet and discharge hoses Remove four screws Key No 25 pull out complete motor pump and macerator assembly If assembly does not slide out easily push forward and pull back sharply several times to free macerator housing from base Remove discharge port Key No 12 and joker valve Unscrew c...

Page 3: ...asher Fiber 2 35445 0000 23 Wearplate Kit 1 37018 0000 24 Lock Washer 10 Stainless Kit 4 25 Screw 4 91027 0011 26 Gasket 1 12558 0000 27 Flexible Impeller 1 6303 0003 28 Body 1 12554 0000 29 Seal Retainer 1 1040 0000 Qty Part Key Description Req Number 30 Slinger 1 6342 0000 31 Motors Motor 12 Volt 1 37064 0000 Motor 12 Volt EMC 1 37064 0900 Motor 24 Volt 1 37065 0000 Motor 24 Volt EMC 1 37065 090...

Page 4: ...derstedt Tel 49 40 53 53 73 0 Fax 49 40 53 53 73 11 THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST 1 Dia 25 4 102 6 152 D Overall Width C G E F 5 16 8 3 1 8 79 B A 10 7 8 12 15 16 5 8 Dia 2 Places 16 2 Leads 11 Long 279 3 1 2 89 7 3 8 187 2 1 2 64 3 7 8 98 4 102 5 3 8 137 5 8 16 MOTOR COVER DIMENSIONAL DRAWING I...

Page 5: ...or service please take your pump into your local pump service center To order pump or parts or for pricing please go to the following links Jabsco Pumps Home Jabsco Pumps stock list PumpAgents com buy pumps and parts online ...

Reviews: