ELECTRICAL  CONNECTIONS  -  Select  a  location  for

the switch and instruction plate, making sure wire leads

from both the toilet and power source can be routed to

the switch. Ensure the panel where installing switch is no

more than 1" thick. Drill a 5/8" mounting hole and install

switch and instruction plate. Use stranded copper wire of

the correct size (determined from the electrical specifi-

cations chart) to connect one side of the switch to the

positive power source. An appropriate size fuse or equiv-

alent circuit breaker (determined from electrical specifi-

cations  chart)  must  be  installed  in  the  positive  power

lead within seven inches of the power source. Connect

the other side of the switch to the orange (positive) motor

lead. Connect the black (negative) motor lead to the neg-

ative side of the battery or grounded buss bar.
NOTICE:  Correct  motor  polarity  (orange  to  positive,

black  to  negative)  is  important.  Reverse  polarity  can

damage  motor  and  void  warranty.  Full  voltage  at  the

motor is required to properly operate the Electric Toilet.

The toilet must be wired in a circuit independent of all

other accessories.

ELECTRICAL SPECIFICATIONS

AMP

FUSE

WIRE SIZE PER FEET OF RUN*

V OLTAGE

DRAW

SIZE

0'-10'

10'-15'

15'-25' 25'-40' 40'-60'

12 Vdc 

16

25

#12

#10

#10

#8

#6

24 Vdc

8

15

#16

#14

#12

#10

#10

* Length of run is total distance from power source to product and back to ground.

OPERATING INSTRUCTIONS

Make sure inlet and outlet seacocks are all open; push button

to  operate.  Operate  until  bowl  is  completely  flushed  and

discharge pump has scavenged water from bottom of bowl.
The Jabsco electric marine toilet will provide years of trou-

blefree service if properly used. It will handle waste and toi-

let tissue. It will NOT handle rags, sanitary napkins or hard

solid objects.
If bowl does not pump out and begins to fill, partially close

inlet  valve  until  bowl  is  cleared  and  completely  pumped

out. Then operate for a few seconds with both valves open

to clear entire toilet and discharge system. For maximum

safety, when toilet is not in use or vessel is unattended,

close both the inlet and discharge seacocks.

To drain for winter lay-up, close inlet valve and operate for

a few seconds until all water is pumped out.
After long periods of non-use, toilet and pump may dry out.

To ease initial start-up, put about one quart of water in bowl

and let stand awhile before initial use.

DISASSEMBLY

Disconnect pumping inlet and discharge hoses. Remove

four screws, Key No. 25, pull out com plete motor, pump

and macerator assembly. If assembly does not slide out

easily, push forward and pull back sharply several times to

free macerator housing from base.
Remove  discharge  port,  Key  No.  12,  and  joker  valve.

Unscrew chopper plate, Key No. 14, by turning counter -

clock wise, facing plate. Prevent shaft from turning by plac-

ing screwdriver in  discharge  port  and  locking centrifugal

impeller  blade.  Remove  macerator  housing.  Loosen

impeller set screw and slide impeller off motor shaft.

Remove four flathead screws and two washers, Key Nos.

20, 21, & 22. Remove the plastic wear plate, Key No. 23,

with sealing sleeve, Key No. 19, and gasket, Key No. 26.

Slide pump assembly off motor shaft. Replace all worn or

damaged parts, clean remaining parts.

ASSEMBLY

Press seal into body with lip facing impeller; be careful

not to cock seal in bore. Install pump body on motor and

position on register. Lubricate impeller bore with pump

grease and install impeller. Position the gasket against

the body and install the wearplate ensuring the two plas-

tic sealing washers are under the heads of the top and

bottom  screws.  NOTE:  The  current  plastic  wearplate

supercedes the earlier brass wearplate and with it the

stainless  steel  wearplate  is  no  longer  used.  Slide  the

rubber sealing sleeve on the motor shaft and push it into

its recess in the wearplate. Relocate centrifugal impeller

on shaft, about 1/8" from the wearplate, and tighten set

screw. Place macerator housing over shaft and centrifu-

gal impeller, put lock washer on end of shaft and screw

chopper plate on shaft and tighten. Install O-ring in O-

ring groove in wearplate surface, a little grease will help

hold in place, make sure inside body surfaces are clean,

line up slot in base with key on macerator housing, slide

pump  assembly  into  base  and  tighten  with  the  four

screws. Turn motor on for one or two seconds to be sure

centrifugal impeller is free.

WARNING

!

Flood hazard.  Close inlet and outlet 

seacocks prior to disassembling toilet.  

Failure to do so can result in flooding 

which can cause loss of property and life.

37068-0000

SOLENOID

www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts

Jabsco Pumps 37010-3092

Summary of Contents for 37010-3092

Page 1: ... provide a separate fresh water tank to supply water to the toilet only DO NOT CONNECT INLET HOSE TO A PRESSURIZED WATER SYSTEM Flood hazard If toilet is installed below the waterline or may be below the waterline at any angle of heel or trim it must be installed with properly positioned vented loops Failure to do so can result in flooding which can cause loss of property and life WARNING CAUTION ...

Page 2: ...iods of non use toilet and pump may dry out To ease initial start up put about one quart of water in bowl and let stand awhile before initial use DISASSEMBLY Disconnect pumping inlet and discharge hoses Remove four screws Key No 25 pull out complete motor pump and macerator assembly If assembly does not slide out easily push forward and pull back sharply several times to free macerator housing fro...

Page 3: ...14 0000 16 Centrifugal Impeller 1 37006 0000 17 Set Screw 1 18753 0492 18 O ring 1 43990 0066 19 Sealing Sleeve 1 37036 1000 20 Screw 2 91009 0096 21 Screw 2 91010 0130 22 Washer Fiber 2 35445 0000 23 Wearplate Kit 1 37018 0000 24 Lock Washer 10 Stainless Kit 4 25 Screw 4 91027 0011 26 Gasket 1 12558 0000 27 Flexible Impeller 1 6303 0003 28 Body 1 12554 0000 29 Seal Retainer 1 1040 0000 Qty Part K...

Page 4: ...diaries 43000 0789 Rev B 43000 0612 Rev D 12 2017 THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST www ittflowcontrol com Copyright 2010 ITT Corporation Printed in U S A All Rights Reserved Form 43000 0612 Rev A 11 2010 1 Dia 25 4 102 6 152 D Overall Width C G E F 5 16 8 3 1 8 79 B A 10 7 8 12 15 16 5 8 Dia 2 Plac...

Reviews: