SAFETY

This section highlights safety warnings for this product. Warnings listed in this section 

will be referenced throughout this document. Please review and understand the entire 

manual before using this product.

Many components are charged with high voltage and/or in movement (fans), even 

after the incoming AC power supply has been disconnected or switched OFF. Wait at 

least 10 minutes for the total discharge of the power capacitors.
Always connect the frame of the equipment to the ground (PE) at the suitable 

connection point.

All electronic boards have components that are sensitive to electrostatic discharges. 

Never touch any of the electrical components or connectors without following proper 

grounding procedures. If necessary to do so, touch the properly grounded metallic 

frame or use a suitable ground strap.
No motor or VFD service should be conducted in the field. All inquiries on service for these 

units should be directed to technical support: 1-877-934-3748
Wireless remote control functions on a 9 VDC battery accessed through the rear 

battery compartment panel on the hand held remote.  For extended battery life, it is 

recommended to remove the battery if the cart is not to be used for long periods.

WARNING

EXPLOSION HAZARD

DANGER

Only used with specified products. DO NOT USE WITH LIQUIDS WITH A 

FLASH POINT BELOW 100ºF (38ºC) OR USE WHERE FLAMMABLE VAPORS 

ARE PRESENT.

The inverter control circuit (ECC3,DSP) and the HMI-CFW08-P are high 

voltage circuits and are not grounded.

Always disconnect the supply voltage before touching any electrical 

component inside the inverter.

ATTENTION

22.6” (575 mm)

35.9” (912 mm)

6.9” (175 mm)

ADJUST

ABLE

37.8 - 41.7 “ (960 - 1060 mm)

Side View

Top View

Front View

13.8” (350 mm)

13.7” (349 mm)

Dimensions

FLEXIBLE IMPELLER

PUMP CART SYSTEM

28 SERIES

Performance Curve

V

era

F

lex

TM

FLEXIBLE IMPELLER PUMP CART SYSTEM

HYGIENIC STAINLESS STEEL HEAD PUMP 2”

 

Specifications and Features

Operating Instructions

Pump with the Variable Frequency Drive (VFD) will operate from 0 GPM 

to 60 GPM utilizing the speed control on the wired remote or wireless 

remote to increase or decrease the motor speed. Please reference WEG 

CFW-08 manual.

VFD Operation

The VFD is pre-programmed at the factory to meet specification 

compatible with the pump/motor assembly. No change to the program is 

possible.
For codes generated on the display of the VFD, or issues that may arise, 

please see the included WEG manual detailing operations and safety 

requirements associated with the VFD. The standard CFW-08 keypad has a 

LED display with 4 digits of 7 segments, 4 status LEDs and 8 keys. 
Functions of the LED display: The LED display shows the fault codes and 

drive status (refer to Quick Parameter Reference, Fault Messages, page 8 – 

16 – WEG manual)
Functions of the “Local” and “Remote” LEDs:  pages 67 - 71
Functions of the FWD/REV LEDs - Direction of rotation pages 67 – 71
Basic functions of the keys: pages 67 - 71

Pump Cart Maintenance

Pump cart tires are inflatable, Follow max recommended pressures as listed 

on the tires.
Cart handle height is adjustable to three levels by removing the socket heat 

cap screws on the vertical riser of the handle tube and adjusting to meet the 

pre-drilled holes, then reinserting the screws to tighten.

ASSEMBLY

1. 

Replace mechanical seal by sliding spacer (if new spacer is required or old spacer 
was removed) onto shaft up to locating shoulder, then lubricate shaft with sanitary 
lubricant.

2. 

Push on seal gently until it engages with spacer. 

3. 

Fit rubber cup and seal seat into wearplate.

4. 

Insert impeller in pump body.

5. 

Fit O-ring in each end of the pump body. 

6. 

Fit wear-plate to body.

7. 

Slide wear-plate and body assembly over shaft.

8. 

Tighten screws to hold body to adapter flange. Torque screws to 10 in. – lbs.

9. 

Fit end cover, with cover o-ring and end cover screws to body. Torque screws to 60 
in. – lbs.

The pump is reversible utilizing the directional change button on the VFD or by reversing the 
impeller manually.

Changing Pump Rotation (looking at end cover):

Clockwise Rotation: 

Insert impeller into pump body with blades bending counterclockwise

Counterclockwise Rotation:

Insert impeller into pump body with blades bending clockwise.

DISASSEMBLY

1. 

Remove the four end cover screws. Remove end cover and O-ring.

2. 

Remove the four screws, holding the body to the motor adapter flange. Slide body, 
complete with impeller and wear-plate, from motor shaft assembly.

3. 

Remove mechanical seal by inserting two screwdrivers behind seal collar, and gently 
lever collar and seal assembly forward on shaft. Use extreme care not to mar shaft 
surface. 

4. 

Remove seal seat and rubber cup from recess in wear-plate.

Certified to US 3A.

Easy strip clean

Minimal shear to thixotropic fluids

Includes basket for fittings, and O-rings

Includes power cord and remote wire retaining brackets (Plug is supplied by 
customer).

Pump Type

Close Coupled, 3A

Body

316 Grade Stainless Steel

Impeller

Sanitary Neoprene

Shaft Seal

Mechanical; Carbon-on-Ceramic

Ports

2” Tri-clamp type

Shaft

316 Grade Stainless Steel

Motor

50Hz, 3 HP 112 IEC Frame, Washdown rated, 
230 VAC 3 Phase. Maximum RPM 1000.

Variable Frequency Drive

230 VAC 1 Phase input, 50 / 60 Hz

Wireless Remote

Operates on standard 9 VCD battery

Weight pump head

30.0 lb (13.6 kg)

Weight complete unit

159 lb (72.0 kg)

Self primes from dry up to

15’ (4.5 meters)

Flows up to

60 GPM (228 LPM)

Pressure up to

37 PSI (2.5 Bar)

Handles viscosities up to

10,000 centipoises

Close coupled hygenics SS pump head/motor/VDF assembly mounted on a

4 wheel cart.

with 8984-0005 impeller

LTR 7426

Wine Cart Performance Test

with 8984-0005

FLOW (US gall/min)

FLOW (Liters/min)

DIFFERENTIAL PRESSURE (p.s.i.)

DIFFERENTIAL PRESSURE (bar)

Reviews: