background image

Range of temperatures settings. 

Settings 

item 

Range 

Factory 

settings 

Description 

HYst 

0.1°C to 1°C 

0.2°C 

Hysteresis 

t Lo 

+ 6°C to + 40°C* 

6°C 

Lower limit of regulated 

temperature 

t Hi 

+ 6°C to + 40°C* 

40°C 

Upper limit of regulated 

temperature 

AL Lo 

– 9°C to + 20°C 

3°C 

Low temperature alarm 

report 

AL Hi 

+ 30°C to + 70°C 

60°C 

High temperature alarm 

report 

* The ranges of 

t Lo 

and 

t Hi 

can´t overlap each

 other

 

 

  Showing the pre-set temperature 

The thermostat always shows the current room temperature in the normal 

mode.  Briefly  pressing the knob will show the temperature which has been 

set for this time. The pre-set temperature flashes 3s then it shows the current 

temperature again. 

  Replacing the batteries 

When the thermostat starts to indicate the Low Batt symbol (

) or stops 

working completely, replace the batteries for new ones. A Low battery report 

is sent to the receiver.  

Note: 

We  strongly  recommend  only  using  alkaline  batteries, 

type AA 1.5V. 

 

Use with the AC-116 receiver 

When the thermostat has been enrolled to a 2-way receiver (AC-116) it can 

indicate by a  blinking exclamation symbol (

!

)  on the LCD of the thermostat 

that communication has been lost. 

You can block the channel to which  the thermostat is enrolled with  a 

different device (magnetic contacts in windows for instance). Blinking of the 

(

▲)

 symbol on the thermostat LCD indicates that the thermostat is blocked. 

Using the AC-116 receiver you can block the control of the thermostats at 3 

levels.  
1 – temperature adjustment (when the 

LOc

 menu is entered it can be unlocked) 

2 – entering the menu (the temperature can be changed but access to the menu is 

blocked) 

3 – Locked completely (control from the thermostat is completely blocked) 

When control is blocked from the AC-116 receiving unit, it is indicated on 

the thermostat LCD display by the key symbol ( ). 

A weekly schedule can be set for each channel and be saved wirelessly to 

the thermostat. This can be done by a AC-116 receiving unit equipped with 

an AC-100LCD touch screen module. The thermostat then starts working as 

a thermostat with a weekly schedule. This option is not programmable directly 

on the thermostat but just from the AC-116 receiving unit. 

Technical specifications 

Power: 

2x AA 1.5 V alkali

ne batteries

 

Lifetime of batteries: 

typically 1 year 

Regulation range

+6°C 

to 

+40 ˚C

 

Temperature regulation sensitivity

adjustable

: ± 0.1- 

1 ˚C

 

Alarm when temperature drops 

below ALLo: 

-9 to 

+20°C  

 

Alarm when temperature exceeds

 ALHi: 

 

+30°C 

to 

+70°C

 

Communication band

868.1 MHz, JA-100 protocol 

RF range

up to 100 m (

open area

Operational temperature

-

10°C to + 70°C (no condensation

Dimensions

66 x 90 x 22 mm 

Complies with

ETSI EN 300220, EN50130-4, EN55022, + EN 60950-1 

Can be operated according to

 

ERC REC 70

-03 

 

JABLOTRON ALARMS a.s. hereby declares that the TP-150 module is in 

compliance with the essential requirements and other relevant provisions 

of Directive 1999/5/EC  and 2011/65/EU.  The original of the conformity 

assessment can be found at 

www.jablotron.com

  -  Technical Support 

section

 

 

Note:

 Although this product does not contain any harmful materials we 

suggest you return the product to the dealer or directly to the producer 

after use. For more detailed information visi

www.jablotron.com

.

 

 

TP-150 wireless indoor thermostat 

2 / 2 

MMC51601 

Reviews: