1. Description 

The TD-101 is an automatic dialing device that transmits prerecorded information via the telephone line. 

The dialer can send two different 10 second voice messages (or one 20 second message) to four phone 
numbers. It can also send two different Numeric messages to two different PAGERS and four digital codes 
to a monitoring station. The desired type of communication is easily selected during installation.  

The dialer has two trigger inputs. The optional model TD-101W can also be triggered remotely with a 

wireless remote control. 

There are three levels of operation for the TD-101: 

standby

,  

user

, and 

installer

. Three light emitting 

diodes on the front of the TD-101 show  what level the dialer is in.    

In

 standby

 mode the TD-101 waits for an input from either of the trigger inputs or from the built in keypad.  

At the 

user 

level (accessible with User Code) you can enter and delete phone numbers, change the 

voice messages, change the user code, or test that the TD-101 is functioning properly. Model         TD-
101W can also "learn“ a remote control code in this level. 

At the 

installer 

level (accessible with Installer Code) you can modify optional functions of the dialer 

and enter data for digital communication with a monitoring station. 

All data is stored in the TD-101's EEPROM memory. So disconnecting the power from the dialer will not 

erase the data. An emergency reset feature can return the dialer to its original factory settings when 
necessary.   

The autodialer takes priority on your telephone line. When triggered, it will switch all other devices 

(phone, fax, PABX) off line. By checking signals on the line (dial, busy or ringing tone) the dialer knows 
what its next response should be. A built in speaker can be used as an audible monitor of the dialer 
function. The telephone line is electrically separate from the power and trigger inputs. The TD-101 has 
specially designed circuits to protect your telephone line from lightning strikes overvoltage. Tamper 
protection is also provided. 

 

1.1. Possibilities of use

  

The TD-101 dialer has a wide spectrum of use: 

 

property protection 

- connected with a house alarm system it can send not only an alarm 

message, but also arm/disarm information or panic signal 

 

emergency calls 

- ill or old people can easily call a doctor or relatives for help using the TD-101. 

The dialer can be triggered by pressing the 

F

 

key, or by an additional push button wired to the 

input. Model TD-101W can also be triggered with  a wireless remote control. 

 

technical information sending 

- the dialer can automatically report failures of crucial devices 

(refrigerator, cooling systems, pumps, heating systems, elevators  etc.) or in connection with a 
suitable sensor it can inform about reaching of a critical level of controlled parameters 
(temperature, humidity, water level etc.). 

 

2. Specifications 

operating voltage 

  12VDC (10-14V) 

current consumption 

stand by  15 mA max. 

 

operating  100 mA max. 

trigger inputs 

IN1 & IN2  separated with optocouplers  

 

option TD-101W  also wireless 

tamper switch 

  1A / 60V max. 

telephone line 

   electrically separated, over voltage protection 

dialing method 

  pulse / tone 

phone number Memories 

voice message  4x 16 digits (Mem1-4) 

 

pager   2x 26 digits (Mem5,6) 

 

monitoring station  2x 16 digits (Mem7,8) 

phone line signal detection 

dialing, busy or ringing tone 

voice message duration 

  2x 10 or 1x 20sec. 

monitoring station protocols 

ADEMCO, SILENT KNIGHT,  SESCOA, FRANKLIN, DCI, 

 

VERTEX, RADIONICS, DTMF 1400, DTMF 2300 

 

 
can be connected to analogue interfaces TBR 21/1998, EG 201 121 V1.13/2000, AS/ACIF S002/2001 
(Australia) 

Summary of Contents for TD-101

Page 1: ...Pod Skalkou 33 466 01 Jablonec nad Nisou Czech Republic E mail export jablotron cz http www jablotron cz...

Page 2: ...1 7 5 Account number programming 11 7 6 Reporting codes programming 11 7 7 Testing the Monitoring Station communication 12 8 Optional functions and parameters programming 12 8 1 Opening of Installer M...

Page 3: ...factory settings when necessary The autodialer takes priority on your telephone line When triggered it will switch all other devices phone fax PABX off line By checking signals on the line dial busy...

Page 4: ...urrent switching off There are many possibilities on how to connect the trigger inputs see examples on page 20 Consider that the dialer reacts only to signals with a duration of 0 1sec or longer Each...

Page 5: ...rm system 20 seconds siren alarm in the system N C or NO contact typical for use with monitoring station trigger selectable 11 2 Use of the dialer only for emergency dialing old or ill people Connect...

Page 6: ...call a mobile phone To program telephone numbers enter DDDD D ME where D is a telephone number keys to or B i e pause Pause can not be in the first position Keys and can also be programmed in tone dia...

Page 7: ...with your PAGING provider 6 5 Deleting telephone numbers Telephone numbers for voice pager messages can be deleted in user mode the green LED is ON see 6 1 entering B ME where E is the memory number...

Page 8: ...ble you can hear tel line signals and voice messages from the built in speaker Example Voice message no 1 will be sent to tel number Mem2 FM 6 9 Changing of the User Code To avoid non authorized acces...

Page 9: ...beep Check also if the voice messages are recorded and that the telephone numbers are stored in corresponding memories see chapter 6 It is impossible to enter the user or installer mode it can be ente...

Page 10: ...lled if the main number is busy Example The main telephone number of the monitoring station will be 811 777 M 7 3 Deleting of Monitoring Station telephone numbers Telephone numbers for MS can be delet...

Page 11: ...1 Example The audible dialing monitor will be enabled F 8 10 Stop function with Ekey Stop function is selectable in the installer mode the yellow LED is ON see 8 1 entering F D where D 0 stop is disab...

Page 12: ...or two voice messages can be selected in the installer mode the yellow LED is ON see 8 1 entering F D where D means number of messages 1 1x 20sec or 2 2x 10sec factory default 2 messages max 10sec eac...

Reviews: