CONTROL PANEL TECHNICAL PARAMETERS

PARAMETER

TYPE: CU2202MD

Dimensions

268 x 225 x 83 mm

Nominal control panel voltage / frequency / 
fuse

~110–230 V/50–60 Hz, max. 0,28 A 
with a fuse F1,6 A/250 V, protection class II

Electrical input power / current

max 23 VA / 0,1 A

Classification of alarm device

Security grade 2 / environment class II

@ according to standards

EN50131-1, EN 50131-3, EN 50131-6, 
EN 50131-5-3 (utilizing a radio module), 
EN 50131-10, EN 50136-1, EN 50136-2

@ environment

Indoor general

@ operational range of temperature / humidity

-10 °C to +40 °C/ 75% RH w/o condensation

Number of code combinations per user, there 
are no disallowed codes in the alarm

10

4

 – (The number of users within a system – 1)

Number of code combinations per user when 
using access cards

10

9

 card codes

EMC

EN 50130-4, EN 55032, ETSI EN 301 489-1, 
ETSI EN 301 489-3 

Electrical safety

EN IEC 62368-1

Power supply protection 

Fuse T1,6 A; 250 V

Backup battery

Lead 12 V / 2,6 Ah

Certification body

TREZOR TEST (no. 3025)

JABLOTRON ALARMS a.s. hereby declares that the CU2202MD is in a compliance 
with the relevant Union harmonization legislation: Directives No: 2014/53/EU, 2014/35/
EU, 2014/30/EU and 2011/65/EU. The original of the conformity assessment can be 
found at www.jablotron.com - Section Downloads.

Note

: Disposing of this product correctly will help save valuable 

resources and prevent any potential negative effects on human 
health and the environment, which could otherwise arise from 
inappropriate waste handling. Please return the product to the 
dealer or contact your local authority for further details of your 
nearest designated collection point.

JABLOTRON ALARMS a.s. | Pod Skalkou 4567/33 | 46601 Jablonec n. N. | Czech Republic | www.JABLOTRON.com

Reviews: