jablotron JK-16 PROFI Installation Instructions Download Page 3

JK-16 PROFI 

3/4 

MGK24401 

10. Keypad operation  

 

 

11. Specifications  

 
Power  

230 VAC, max 0.1 A, supervised, class II 

Power supply 

A type (EN 50131-6) 

Backup battery  

12 V, 2.26 Ah, normal life time 5 years 

Backup power output   13VDC,  the max. permanent current is 0.4  
 

or 1A for max. 15 min (1 cycle per hour),  

Consumption of the control panel is  

30 mA; JA-60E 25 mA 

Hard-wired inputs  

4 input zones, selectable triggering: 

Wireless zones 

16 zones (2 detectors can be enrolled to each  

Wireless controllers  

max. 8 (JA-60F,  RC-22, RC-44) 

Access codes 

master code and 14 user codes.  

Wired outputs 

Alarm relay dry contacts 1A/60V; 

Programmable outputs  PgX , PgY connect to the GND max. 0,1 A 
Siren output  

12 V, 0.7 A 

Working frequency*  433.92 MHz; digital hopping code; supervised 
communication 
Comply with 

EN 50131-1, EN 50131-6 

Security grade 

2 (low to medium risk) 

Environmental class 

II indoor – general (-10 to 40oC) 

Safety 

EN 60950-1 

EMC 

ETS 300683 

Radio characteristics 

ETSI EN 300220 

Can be operated according to  

ERC REC 70-03 

 

 

Jablotron Alarms a.s. hereby declares that the JA-83K “OASiS“ 
control panel is in compliance with the essential requirements and 
other relevant provisions of Directive 1999/5/EC. The original of 
the conformity assessment can be found on the web site 
www.jablotron.com, Technical Support section. 

 

Note:

 Dispose of batteries safely depending on the type of the 

batteries and local regulation. Although this product does not 
contain any harmful materials we suggest you to return the 
product to the dealer or directly to the producer after usage.

 

Entry 

Function 

User code 

Arming / Disarming (Setting\Unsetting) 

F1 / 

 

Arming without a code 

F2 / 

 

Partial arming  

F3 / 

 

Door lock opening 

F4 

Memory reading 

F5 

New master code (example: 

F5 1234 2789 2789

F6 

User codes setting (example: 

F6 1234 03 3344

F7 / 

 

Disarming under duress  

F8 

Appliance control (F81 = ON,  F80 = OFF) 

F0 M.code 

User test mode (example F0 1234)  

Escape & fault detail reading 

Motion detector
JA-60P

Doors, Windows
JA-60N

Wireless keypad
JA-63F

Remote control
RC-4x

Indoor siren
UC-260
(230 V AC)

Control panel
JA-63KR

Power (230 V AC)