jablotron JK-16 PROFI Installation Instructions Download Page 2

JK-16 PROFI 

2/4 

MGK24401 

 

4.  Detector and accessory installation 

 

a)  Install  the 

JA-60N  magnetic  detector  onto  the  door

 

(antenna pointing up or down)

 

 

 

b)  Install the 

JA-60P PIR motion detector

 

c)   Select 

Instant  or  Delay  reactions

  via  the  DIP  switches 

inside the detectors. 

d) 

Connect  the  detector’s  batteries 

(pull  out  the  red  tape  to 

activate the batteries) 

e) 

Attach the keypad to the desired location 

 

f)  Plug the UC-260

 wireless siren 

into a power socket 

g)  Test the wireless

 doorbell button 

and install it.

  

 

 

5.  Enrollment of additional accessories 

 

If you install 

additional detectors

 (max. 32), you have to enroll 

them. The system should be in 

P mode 

(if not enter F0 6060): 

a) 

Press 1 to enter enrollment

 mode* 

b) 

The  next  free

  detector 

position  will  be  displayed  on  the 

keypad. 

 

c) 

Install batteries

 into all new detectors step by step to enroll 

them (system will automatically offer the next free position) 

d)  To 

scroll through sensor positions, 

press 1 (up) or 7 (down)  

e)  To enroll a 

second detector

 to an occupied position press 5 

before you install the detector’s batteries  

f)  To 

exit enrollment

 

mode

 press the N key   

 

The  wireless  keypad 

(JA-63F)  enrolls  after  you  install  its 

battery while in 

enrollment

 mode. 

The remote control

 (RC-4x) enrolls after you press and hold 

both 

and

 buttons while in 

enrollment

 mode. 

The  wireless  outdoor  siren

  (JA-63A)  enrolls  after  it  is 

powered up while in 

enrollment

 mode   

To  enroll  the  control  panel  to  UC  receivers

  enter 

299

  on 

the keypad while in P mode 
Check individual device manuals for more details 

 *Enrollment mode will also start after shorting the reset pins 

in the control panel while it is in P mode. 

 

6.  Detector and controller testing 

 

a)  The system should be in 

P mode 

(if not enter F0 6060) 

b) 

Trigger detectors

 – their addresses (1=door and 2=PIR) should 

be  indicated  (if  the  PIR  detector  does  not  react,  re-enter  test 
mode by opening and closing its cover) 

c)  Press 

button 

 

  on  the  RC-4x  remote  control 

– 

c2

  will  be 

indicated   

7.  To measure the strength of the radio signal  

 

a)  While in 

P

 mode, press 

1

 and then using 

7

 scroll to position 

1

  

b)  Press 

to start measuring  

c) 

Activate

 the door detector to view its signal strength 

d)  Using  the 

1  key,  scroll  to  the  next  position

  (2  PIR)  and 

check  its  signal  strength  (if  the  PIR  detector  does  not  react, 
reenter its test mode by opening and closing its cover) 

e)  Repeat step d) to check all enrolled items. The 

wireless keypad 

(c1) signal is indicated after you trigger its tamper. 

The

 

remote 

control

 (c2) is indicated after you press it’s 

button.   

f)  Change the location of an item if its signal is 

lower than 2

 

g) 

Return to P

 mode by pressing the 

N key

 

 

8.  Programming the system 

 

a)  The system should be in 

P mode 

(if not enter F0 6060) 

b)  Using the following sequences you can program: 

 

Function 

Sequence 

Comments 

Your 

installer code*

 

5 xxxx xxxx 

6060 

factory default 

xxxx new code

 

Exit delay 

20x 

3

=30sec factory def. 

Entrance delay 

21x 

3

=30 sec factory def. 

Alarm duration 

22x 

4

=4min factory def. 

Time & date 

4 hh mm DD MM YY

 

See control panel installation manual for more details. 

 

Must be changed 

 

 

9.  Finishing the installation 

a)  Fill in the information on the sticker label and attach it inside 

the keypad cover. 

b)  Switch the system to standby (by pressing the N key) 
c)  Instruct the user on how to operate the system 

 

 

A

attach

C

open

B

click

rear tamper
lever 

Don't tight 
this screw

2

2,5

1,5

1

0,5

1,6

3,7

12

range [m]

height

[m]

120

ş

12

m

zone A

zone B

zone C

zone A

zone B

zone C

JA-60P coverage

avoid locations against windows or close to a heater