The JA-80X communicator 

4 / 4 

MKR51103 

5. 

Communicator RESET 

 

 

sequence 78080

 

To reset the communicator to its factory default settings enter: 

 

 

 

78080 

Note:  Performing  a  RESET  does  not  affect  the  voice  message 
recordings. 

 

6. 

Specification 

Dialling method 

DTMF 

Phone line check 

enable / disable 

Voice message phone numbers 

up to 4 

(voice message assigned to one of the 5 alarm types) 
Digital data transmission to an ARC  

CID 

(Alarm Receiving Centre) 

(Contact ID) 

Complies with EN 50131-1: 
Security 

grade 2 

Alarm transmission system class 

ATS 4 

Environmental class 

2 Indoor general (-10°C to + 40°C) 

Further standards: 

EN 50136-1-1, EN 50136-2-1, ANSI C63.4, 

 

EN 55022, EN 50130-4, EN 60950-1 

Analogue interface connectivity 

EN 301437, TBR 21 

 

 

 
 

Jablotron  Ltd.  hereby  declares  that  the  JA-80X  is  in 
compliance  with  the  essential  requirements  and  other 
relevant provisions of Directive 1999/5/. 
The original of the conformity assessment can be found 
on  the  web  site 

www.jablotron.com

,  Technical  Support 

section. 

 

Note

:  Dispose  of  batteries  safely  depending  on  battery 

type  and  local  regulations.  Although  this  product  does 
not contain any harmful materials we suggest you return 
the product to the dealer or directly to the manufacturer 
after use. 

 

A brief list of programming sequences 

 

Function 

Sequence 

Options / Notes 

Factory default  

Programming telephone 
numbers for voice 
reporting 
 

71 M xx  x *0 

= memory 1to 4 

xx  x 

= tel. number (max. 16 digits) 

*0

 

is the entry terminator 

71M*0 erases memory M 

 
M1 to M4 erased 

Voice message recording  72 

To be entered on the system keypad during the ringing period. 

(English) 

Filtering reported events  73nx 

= Group of event types 

 

1 = All events 

 

2 = Alarm triggering events 

 

3 = Alarm cancellations 

 

4 = Setting/Unsetting (Arming/Disarming) 

 

5 = Faults 

 

6 = Maintenance events only 

 

7 = Regular (periodical) reports 

x = 1 

Report    

x = 0  

No report 

 
 

7311 

 

 

ARC communication test  74 

 

 

ARC phone numbers 
 

75Mxx  x*0 

M = 1 

  main ARC 

M = 2 

  backup ARC 

Both M1 and M2 erased 

Installation ID for ARC 
use 

76xx  x*0 

 

0000 

Ringing period for remote 
access 

77n 

n = 1-8 

duration in multiples of 5 seconds 

n = 9 

the call is answered after ringing for the second time 

n = 0 

the call is never answered 

n = 0 

Communicator RESET  

78080 

 

 

ARC reporting mode 

791x 

x = 0 

no reports 

x = 1 

backup to ARC1 

x = 2 

backup to ARC2 

x = 3 

always report 

7910 

Limited event-reporting 

792x 

x = 0 

limited reports for the 2

nd

 tel. number 

x = 1 

all events reported to all numbers 

7921 

Telephone line 
monitoring 

793x 

x = 0 monitoring

 disabled 

x = 1

 

monitoring

 enabled

 

7930 

Sensitivity to signals on 
the telephone line 

794x 

x = 0 

basic sensitivity 

x = 1 

higher sensitivity 

7940 

Busy – tone detection 

795x 

x = 0 

busy-tone detection disabled 

x = 1

 busy-tone detection enabled

 

7950 

 

 