jablotron JA-80X Installation Manual Download Page 2

The JA-80X communicator 

2 / 4 

MKR51103 

3 – Record message No. 3 (Fire) 
4 – Record message No. 4 (Tamper) 
5 – Record message No. 5 (Panic) 
6 – Record message No. 6 (Fault) 
7 – Record message No. 7 (Welcome to OASiS) – greeting 
8 – Record message No. 8 (Enter your access code) 

 

Pressing the key invokes a timer with beep indication. Five beeps 

are to be heard in total with the last beep extended. After this the 
recording  starts  –  you  record  a  message  by  speaking  into  the 
phone’s microphone. The message duration is limited to 9 sec for 
message No. 1, and to 3 sec for any of other messages. 

After  being  recorded,  the  message  is  immediately  re-played.  A 

message  ending  is  indicated  by  two  beeps.  Replaying  all 
messages 

(0)

  can  be  terminated  by  pressing 

*

.  The  recording  of 

any message can be terminated by pressing 

#

 or by hanging up. 

 

Recording the voice message is stopped after  hanging up. 

 

Notes:

 

x

You can also remotely record or modify voice messages via a 
phone  in  a  call  to  the  control  panel.  This  requires  the  control 
panel to be in Service mode (on the phone keypad, you enter 
72x as described above). 

x

You can change recorded messages anytime using the above 
procedure.  Messages  are  stored  in  a  non-volatile  memory  so 
the  JA-80X  will  not  forget  them  when  its  power  supply  is 
disconnected.  

3. 

ARC reporting 

Contact ID (CID) protocol is used for communication with Alarm 

Receiving  Centres  (ARC).  If  at  least  one  phone  number  is  pre-
programmed  for  ARC  reporting  then  the  communicator  tries  to 
send  a  report  about  any  event  detected  by  the  control  panel  (as 
requested  for  ARC  reporting).  Events  are  reported  in  the  same 
order  as  they  are  detected.  A  successfully  transferred  report 
causes a “Report sent to ARC” event report to be stored in control 
panel memory. 

If transfer to ARC1 is not successful, the communicator starts the 

transfer  to  ARC2  depending  on  whether  a  second  ARC  is  pre-
programmed.  If  the  transfer  to  ARC2  is  also  not  successful,  the 
communicator tries to transfer the report to ARC1 again and this is 
repeated four times. Unsuccessful transmission results in “Report 
not sent to ARC” after eight (four) attempts. Then a standard voice 
message is sent to the phone numbers according to the event and 
settings. After that there are two other attempts (cycles) to deliver 
the message to the ARC after 5 minutes and after 10 minutes. 

An  undelivered  report  is  stored  in  the  memory  and  is  reported 

together with the next report – if possible. 

 
Note: Contact ID protocol ensures that all the relevant events are 

reported  automatically.  An  idea  of  the  data  format  is  provided  in 
the table below. 

 

3.1. 

ARC phone numbers  

 

 

sequence 75 Mxxx  xx*0

 

To program tel. numbers of requested ARCs enter: 

75Mxx  .x*0 

where: 

is the ARC memory index: 1=main, 2=back-up 

xx..x 

is the ARC phone number (max.16 digits) 

 
To erase a number from memory M enter:  

75M*0 

 

3.2. 

Installation (alarm system) ID for ARC use 

 

 

 

sequence 76 Mx..x*0

 

The installation’s ID number which is sent to an ARC with every 

report can be programmed with: 

76x..x*0 

where: 

xx.x 

is the installation ID number which identifies your 
premises 

If  a  hexadecimal  form  is  needed  for  the  ID  specification,  use 

digits prefixed by “*” for alphabetical characters: *1 = A to *6 = F. 
Example: The sequence 7615*1*5*0 will program the hexadecimal 
ID 15AE. 

3.3. 

Filtering reported events

 

 

 

 

sequence 73 nx

 

Reported  events  can  be  filtered  according  to  their  type.  To 

enable/disable  reporting  events  of  a  particular  type  (or  group  of 
types) enter: 

73nx 

where:  

is a group of event types 

 

 

1 – All events 

 

 

2 – Alarm triggering events 

 

 

3 – Alarm cancellations 

 

 

4 – Setting/Unsetting (Arming/Disarming) 

 

 

5 – Faults 

 

 

6 – Maintenance events only 

 

 

7 – Regular (periodical) reports 

 

 

is the Enable/Disable attribute 

 

 

1 – Report 

 

 

0 – No report 

 

The factory default setting is 

7311

 

3.4. 

ARC report structure 

A  report  to  an  ARC  sent  using  CID  protocol  consists  of: 

installation  ID  (premises  identification),  event  code,  subsystem 
number and the number of the source (device or code). 

 

Report code table 

 

Report code

Event 

1130 / 3130  Intruder alarm – instant / restored 
1134 / 3134  Intruder alarm – delayed / restored 
1110 / 3110  Fire alarm / restored 
1120 / 3120  Panic alarm / restored 
1461 / 3461  Number of incorrect code-entries exceeded alarm / 

restored 

1140 / 3140  Alarm triggered during control panel power-up / restored 
1137 / 3137  Tamper alarm / no tampering 
1144 / 3144  Device tamper alarm / no tampering 
1406 

Alarm cancelled by user 

1401 / 3401  Unsetting / setting 
3402 

Partial setting 

3408 

Codeless complete setting 

1354 / 3354  External communication fault / restored 
1300 / 3300  Fault (except device) / all faults restored 
1330 / 3330  Device fault / all faults restored 
1301 / 3301  Mains dropout longer than 30 minutes / restored 
1302 / 3302  Battery fault (except devices) / all battery faults restored 
1384 / 3384  Device battery fault / all battery faults restored 
1306 / 3306  Switching to Service Mode / Leaving Service mode 
1661 / 3661  PGX ON/OFF 
1662 / 3662  PGY ON/OFF 
1355 

Radio communication jamming present 

1350 / 3350  Internal communication fault / restored 
1602 

Communication test 

1138 

Unconfirmed alarm 

1351 

Communication fault to ARC1 

1393 

Annual check request 

1551 / 3551  Communicator blocked / restored 

 

List of source numbers 

 

Source number 

Source 

701 

Control panel 

731 

Communicator 

741 

Wired keypad 

001 – 050 

Devices 01 – 50 

500 

Master code 

599 

Service code 

501 – 550 

Codes 01 – 50 

 

Subsystem: 01 in all reports 
In a split system, for setting and unsetting: 02 = A, 03 = B 
For partial setting: 02 = A, 03 = AB 

 