background image

JA-120PC (90) PIR motion BUS detector with a 90° verification camera

JA-120PC (90) BUS PIR motion BUS detector with a 90° verification camera

2 / 2

MMP53102

the number of taken and transferred photos may be tripled (18/24 photos). 
Applies to Instant/Delayed reactions.

Installation recommendations, cautions 

Several JA-120PC (90)s can be installed in the system. However, triggering 

several detectors at the same time will extend the transmission time of photos 
to the control panel and to the external storage. Complete transmission can take 
a few minutes. 

Installation in the corner of a room requires more attention during testing 

due to possible reflections of the flash on the photographed scene (especially 
in the dark).

In order to take a photo using a PG output, use the 

F-Link 

software and

set the 

Impulse

parameter in the 

PG outputs / Function

menu to a time of at 

least 1 min. The PIR is limited to taking 1 requested photo by PG status per 
minute.

The number of pre-alarm photos taken by a PG output is limited to 40 

photos/day/control panel. The photo counter is reset at 00:00 hrs. Alarm 
photos and photos requested in MyJABLOTRON have no limitation.

When you start transferring the pictures to MyJABLOTRON or external 

mass storage, it’s necessary to take into account the cost of data transfer 
to be paid to your GSM provider When LAN communication is not available.

Detection characteristics

The PIR detector has a 90°/12m coverage – see the picture below. 

The detection characteristics of the PIR part has no influence on the camera 
part of the detector. 

Warning:

-

The lens cannot be changed for other types. 

-

The camera has a viewing angle of 90°, the camera flash has a range 
of 3 m.

Saving and browsing the photos

Every photo is taken twice: the first in low resolution (LQ = 320x240 pixels), the 

second in high resolution (HQ = 640x480 pixels). 

All of the exposures are saved into independent folders Foto_LQ and Foto_HQ 

on the Micro SD card. When the card’s capacity is full, the oldest photos will be 
replaced with new ones. Photos saved on the micro SD card can be browsed 
in a photo browser on a PC. 

Note

: Some antivirus software may write its own data on the Micro SD card. 

The detector will automatically format an SD card marked this way. SD card 
formatting erases all data which has been saved. For more information about 
formatting see 

Formatting the Micro SD card .

Photos are sent to the control panel in LQ. You can browse through these 

images in 

F-Link

and 

J-Link

software, event memory

by clicking on an event 

called 

New image

. Pictures are displayed in LQ, if you click on 

Detail

you can get 

second-exposure photos (HQ). Images can be searched and browsed by a file 
manager or picture browser. In order to display the photos this way it is necessary 
to start 

F-Link (J-link)

software, be logged into the control panel as a service 

technician or Administrator and then load the control panel memory. 

Disc: Flexi_log /Foto. 

Here are all the photos which have been sent to the control 

panel (LQ) and photos which have been requested in 

Detail

(HQ).

Picture transmission from the control 

panel

It’s necessary to choose one of these options in order to send photos to the user:

Transfer of pictures to MyJABLOTRON

When the customer uses MyJABLOTRON services, then the customer has 

direct access to the photos from this service. Parameter settings 
of the transfer of pictures are done during the panel registration. 
All the photos are delivered and visible in MyJABLOTRON. Every single 
photo can be requested in HQ resolution. There you can also choose 
telephone numbers (for SMS) or e-mail addresses which will receive 
a message when a new picture is taken. MyJABLOTRON can request a new 

picture without PG output activation (see

Installation recommendations, 

cautions)

.

MyJABLOTRON respects permissions of individual users concerning 

photo verification accordingly to sections to which the users have access 
(for example, a user from section 1 cannot browse through photos from 
section 2)

Transfer of pictures to external mass storage

If MyJABLOTRON is not available, photos can be transferred to external mass 

storage 

http://img.jablotron.com

. Communication parameters are preset 

in the factory and are activated when the first PIR detector with a camera 
is enrolled in the system and after agreeing with pictures transfer. 

When communication works properly the user must create an account 

at 

http://img.jablotron.com

by entering the login and password, and then 

filling in the registration code of the control panel which will make photos
available for browsing. The registration code is on the control panel PCB 
or you can read it via 

F-Link

software, 

Communication

tab, 

Registration 

code

field. 

Reports of new photos stored in this mass storage can be sent 

to an e-mail. 

Note

: If there are more detectors in the premises, all photos will be visible 

to all people with access to the created premises regardless of the sections 
assigned to them. 

Photos stored at 

http://img.jablotron.com

are available only in LQ quality. 

Photos in HQ quality cannot be requested.

In both cases sending reports straight from the control panel will normally 

work. When the picture is saved in

MyJABLOTRON or

http://img.jablotron.com

, the control panel will send an SMS report to all 

users depending on the settings in 

F-Link

,

User reports

tab, 

Alarm photo

settings. Sent SMSes include an http link to display the photo. The photos 
can also be browsed on mobile phones with a connection to the internet.

WARNING:

-

This detector allows you to take photos by PG output reaction or from 
MyJABLOTRON even when the system is unset. The manufacturer 
strictly warns the user that the detector has to be used within the limits 
given by particular laws or norms, especially laws about the protection 
of personal privacy. 

-

The use of the detector is also subject to regulations on the protection 
of personal data and the manufacturer recommends that users be aware 
of the obligations applicable to the operation of CCTV.

-

According to these regulations users have an obligation to ensure 
the approval of persons in range of the detector during the acquisition 
of video recordings or the obligation to indicate the image capture area 
by information tables.

Formatting the Micro SD card

The detector is supplied with a formatted Micro SD card (15). The yellow 

indication LED (16) is turned off in normal detector mode. Slow LED flashing
indicates that the card was removed while data was being written on it, 
or it has been changed for another SD card. The detector will work normally 
with a new SD card only if the detector performs a card formatting. 
Formatting the SD card is started by pressing the tamper contact (13). 
The formatting procedure is indicated by quick flashing of the yellow LED 
indicator (16). During this process all photos on the SD card will be erased, 
however a backup of the photos is in the event memory log, alternatively 
in external storage.

Technical specifications

Power

from the control panel BUS +12 V (+9 ... +15 V)

Current consumption
- nominal for the backup supply calculation

5 mA

- maximum for cable choice

250 mA (with high flash intensity)

Recommended installation height

2.5 m above the floor

PIR detection angle / detection coverage:

90°/12 m

Horizontal camera capture angle

90°

Range of the flash

max. 3 meters

Camera resolution

LQ 320x240; HQ 640x480 pixels

Photo size LQ/HQ (typically)

2-20kB / 2-64kB (6kB / 35kB)

Typical (LQ) photo transmission time to the control panel

up to 20 s. (10 s)

Ideal (HQ) photo transmission time to the control panel

up to 130 s (60 s)

Typical photo transfer time to the server

15 s / GPRS; 2 s / LAN

Dimensions, weight

110 x 60 x 55 mm, 102 g

Classification

Security grade 2 / Environmental class II

- according to

EN 50131-1, EN 50131-2-2

-

operational temperature range

-10 to +40 °C

-

operational environment

indoor general

- certification body

Trezor Test s.r.o. (no. 3025)

Also complies with 

EN 50130-4, EN 55022

JABLOTRON ALARMS a.s. hereby declares that the JA-120PC 
(90) is in a compliance with the relevant Union harmonisation 
legislation: Directives No: 2014/30/EU, 2011/65/EU. The original 
of the conformity assessment can be found at
www.jablotron.com - Section Downloads.

Note:

Although this product does not contain any harmful 

materials we suggest you return the product to the dealer 
or directly to the manufacturer after use.

Top view

Side wiew

Reviews: