The JA-114E Bus access module with LCD, keypad and RFID
5.
Entrance delays / alarms on segment
– the module indicates
entrance delays and alarms on a specific segment.
6.
Wake-up by pressing
– the module optically and acoustically
indicates after the front cover has been opened and also when a
button or segment has been pressed.
Acoustic indication
It can be set regardless of the module’s optical indication and sleep
mode. The module can indicate entrance / exit delays or alarms. During
valid authorization (by user code or RFID card), the acoustic indication
of exit delays is supressed. By pressing the indication button the
module is muted permanently. Entrance delays and alarms are
indicated until their times expire, but only if the activation button is not
pressed.
Technical specifications
Power
from control panel digital bus (9…15 V)
Current consumption in standby mode
15 mA
Current consumption for cable selection
50 mA
Each additional control segment
0.5 mA
RFID frequency
125 kHz
Operating temperature range
-10 to +40 °C
Operational environment according to EN
50131-1 II. Indoor general
Classification
Grade 2
according to
ETSI EN 300330, EN 50131-1, EN 50131-3,
Also complies with
EN 50130-4, EN 55022, EN 60950-1
Can be operated according to
ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-114E
module is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. The original of the
conformity assessment can be found at
www.jablotron.com
-