The JA-114E Bus access module with LCD, keypad and RFID 

5. 

Entrance delays / alarms on segment

 – the module indicates 

entrance delays and alarms on a specific segment. 

6. 

Wake-up by pressing

 – the module optically and acoustically 

indicates after the front cover has been opened and also when a 
button or segment has been pressed. 

Acoustic indication 

It can be set regardless of the module’s optical indication and sleep 

mode. The module can indicate entrance / exit delays or alarms. During 
valid authorization (by user code or RFID card), the acoustic indication 
of exit delays is supressed. By pressing the indication button the 
module is muted permanently. Entrance delays and alarms are 
indicated until their times expire, but only if the activation button is not 
pressed. 

 

Technical specifications 

Power 

from control panel digital bus (9…15 V) 

Current consumption in standby mode 

15 mA 

Current consumption for cable selection 

50 mA 

Each additional control segment 

0.5 mA 

RFID frequency 

125 kHz 

Operating temperature range 

-10 to +40 °C 

Operational environment according to EN 

50131-1 II. Indoor general 

Classification  

Grade 2 

according to  

ETSI EN 300330, EN 50131-1, EN 50131-3, 

Also complies with  

   EN 50130-4, EN 55022, EN 60950-1 

Can be operated according to 

ERC REC 70-03 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-114E 
module is in compliance with the essential requirements and other 
relevant provisions of Directive 1999/5/EC. The original of the 
conformity assessment can be found at 

www.jablotron.com

 - 

Technical Support section 

 

Note:

 Although this product does not contain any harmful 

materials we suggest you return the product to the dealer or 
directly to the producer after use. For more detailed 
information visit 

www.jablotron.com

 