The JA-114E Bus access module with LCD, keypad and RFID 

The access module is a component of the JABLOTRON JA-100 system

Its modular architecture enables users to create a combination whose size of 
installation perfectly meets their needs. The device should be installed by a 
trained technician with a valid certificate issued by authorized distributor.

 

 
The module comprises first a control segment (1), an LCD display (4), an 

RFID chip card / tag reader and keypad (5) . The JA-192E segments can be 
used to extend the JA-114E unit by the required number of segments (the 
max. allowed amount is 20 on one unit). The tilting keypad cover (7) can be 
removed if the user prefers permanent access. 

It also works as an RFID 

card / tag reader

 

 

Figure 2: 8 – Connector for control 
segments; 9 – production code;  
10 – BUS terminals; 11 – tamper 
contact 

 

Figure 1 : 1 – control segment; 2 – segment buttons; 3 – backlit activation 
button; 4 – LCD; 5 – access module with RFID reader; 6 – tabs for module 
opening; 7 - cover screws 

Installation 

1.  Press the four tabs (6) on the sides and release the keypad from the 

plastic base.  

2.  When installing more control segments, first remove the socket cover on 

the 1

st

 segment.  

3.  Remove the transparent plastic cover from the segments (by levering on 

both sides of the segments near the buttons). 

4.  Always connect the segment wires to the connector of the previous 

segment and click them into each other (we recommend coiling the wires 
by turning the segment by 360° – this will prevent any possible damage to 
the wires between the plastic parts). Use this method to install all the 
required segments. Finally, push the socket cover in.  

5. Push 

the 

cable through the plastic base and attach it 

to the selected 

place together with the segments 

using screws.

 If more segments are 

required, fix them onto the wall using screws as well. 

6.  Connect the BUS cable to the BUS terminals (10).  

 

When connecting the module to the BUS, 
always switch the power off.

 

7.  Insert the module into the base. 
8.  Proceed according to the control panel installation manual. Basic 

procedure: 
a.  When the device is switched on, the yellow backlit activation button 

(3) starts flashing repeatedly to indicate that the module has not 
been enrolled into the system.  

b. Go 

to 

the 

F-Link

 software, select the required position in the 

Devices

 window and launch the enrollment mode by clicking on 

the 

Enroll

 option. 

c.  Press the backlit activation button (3) above the screen – the 

module is thus enrolled and the yellow LED indicator goes off.

 

 

9.  When you have completed the installation, insert descriptive labels onto 

the segment transparent covers and close them, see figure 3. Label 
printing is a part of the F-Link software (

Devices

 window, at the module 

position – 

Internal settings

). 

Notes: 

The module can also be enrolled to the system by entering its 

production code (9) in the F-Link software or using a bar code scanner. 
All numbers stated under the bar code shall be entered (1400-00-0000-
0001). 

To comply with the EN 50131-3 norm it is necessary to fix the cover 

tabs (6) by the screws from the accessories. In picture no 1 the cover 
tabs are displayed and marked by the arrows.

 

 

 

 

Figure 3: Inserting a label into a control segment 

Unit modifications  

If you need to change the unit’s individual segments, it is possible to 

separate them by levering the corresponding separating gaps from one side 
(sideways from the buttons). Make sure the system BUS is disconnected. 

Setting the properties 

Go to the 

Devices 

window in the F-Link software. When you are at the 

module position, use the 

Internal settings

 option. The particular unit is 

displayed and it is possible to set its properties. Internal settings is separated 
into 2 basic tabs: 

Segments

 and 

Settings

It is possible to set the required functions for individual 

segments

 (control 

of sections, section status signalling, alarm triggering, PG output control, PG 
output status signalling, etc.). More details are available in the F-Link 
software. 

3

rd

 optional setting tab 

Common segment

 – settings and function 

description 

A common segment (up to 2 of them allowed on one module unit) 

simulates the simultaneous pressing of several segments which are placed 
on this module and which control sections. 

In the Segments 

tab and select 

the specific segment function called 

Common segment A (B)

. Then in the 

new tab 

Common segment

 select the segments which will be operated en 

bloc.  

Note: A module has to be equipped with a minimum of 3 segments otherwise 

this function can not be used. 

The selected sections will all be set / unset after pressing a button on the 

common segment.  

If the states of the segments which are operated by the 

common segment

 

are mixed, then only the segments that need changing will be set / unset. 

If 

partial setting

 is enabled for some segments, then the common segment 

respects this: 1

st

 press = partially setting, 2

nd

 press = full setting. It is not 

suitable to combine a common segment with a common section 

The indication of the 

common segment

 is: all segments unset = green, 

some set (partially set) = yellow, all sections fully set = red.  

In the 

Settings

 tab you can set all other module functions like acoustic 

signalling, backlight intensity, RFID reader mode, optical and acoustic 
indication, LCD display settings, etc. Details related to settings can be found 
in the installation manual of the control panel and of course in the tooltips 
displayed by the F-Link software. 

Optical indication 

Activation button

 – indicates the system status. No light – sleep mode, 

green light – everything OK, green flashes – authorisation performed, red 
flashes – alarm, yellow light – fault, yellow flashes – not enrolled to the 
system, yellow double flash – Service mode. 

Note: The activation button doesn´t indicate module tamper activation in 

Service mode. 

Segments

 – don´t indicate a thing when Service mode is entered or when 

the segment has the function None. The optical indication of a PG segment 
can be inverted. The only exception for segment indication is when a mains 
fault has been detected, then this setting is automatically disabled. 

Module can be preset to the following 6 indication levels: 

1. 

Indicates permanently

 – BUS modules indicate permanently only if 

an external power supply is connected. Without an external power 
supply it indicates the same as option 2. When the mains is restored 
the module indicates permanently again. 

2. 

Section / PG status change on keypad

 – the module indicates 

when the section / PG status has been changed. The status change 
is indicated on the specific segment. Entrance delays and alarms are 
indicated by the whole module. 

3. 

Section / PG status change on segment

 – the module indicates 

when a section / PG output status has been changed. A segment 
status change, an entrance delay and an alarm is indicated on a 
specific segment.  

4. 

Segment status change on keypad

 – The module indicates when 

the status of a segment has been changed (setting, unsetting, PG 
ON, PG OFF). The change of the status is indicated only on the 
specific segment. 

The JA-114E Bus access module with LCD, keypad and RFID 

 