H-915  installation manual   

11/6 

TBT502 01 

[

] COMMANDS LIST 

All the commands bellow can be  used only  when the control panel is in the  standby mode and is disarmed. 
 

[

] [0]

 -

 Quick arming

. You can use this command instead of your access code to arm the system. It can be 

used only for arming, not for disarming. This command works only if quick arming enabled in installer programming level, 
section 4. 
 

[

] [1]

  -

 Alarm memory display

. You can recall the information about the last alarm with this command. 

A blinking zone LED shows which zone  triggered the last alarm. To switch the display back to  normal operation, press 
[

∗]

[3] or rearm the system. 

 

[

] [3]

 - 

Switching OFF the alarm memory display

. The display switches back to normal operation. 

 

[

] [5] [MASTER CODE]

 - 

Entering of USER PROGRAMMING LEVEL

 (factory default master 

code is 1234). Eight different codes (from code 0 to 7) can be programmed in this level: new master code (0), up to five 
access arm-disarm codes (1 - 5), a PANIC code (6) and a "One Time Use" code (7) may be programmed. Entering of the 
programming level is confirmed by eight short beeps and  the ERROR LED being permanently lit. 
Press

 [#] to exit the programming level

. Remember, if no keypad entry is made for more than 1 minute,  the system 

will return to the standby mode automatically. 

 

Programming new codes: 
1/

 Enter user programming level pressing [

] [5] [MASTER CODE] 

2/

 To change master code, press [0] (confirmed with short and long beeps) then enter new 4 digit code (confirmed with 

two short beeps if entered correctly). Master code can be only changed, it can not be erased  

3/

 To program access code number one, press [1] (confirmed with short and long beeps) and enter 4 digit code 

(confirmed with two short beeps if entered correctly). 

4/

 To remove access code number one, press [1] [

5/

 Follow instructions in 3/ or 4/ for programming or removing any of other access codes from 1 to 5  

6/

 You can program the PANIC code as code number six. This code can also be used for disarming, but it triggers a 

silent panic alarm every time it is used. This feature can be very useful in the case you are forced to operate the alarm 
system under pressure. Follow instructions in 3/ or 4/ for panic code setting or removing if you do not want this function. 

7/

 The code number seven works as "One Time Use" code if programmed. Follow instructions in 3/ or 4/ for its 

programming or removing. The "One Time Use" code can be used for arming/disarming control, but this code is 
removed automatically in the moment when used once for arming.  

NOTE: If you press [9] in user programming level the H-915 control panel will send information about events history to 
the special serial interface (printer) which can be connected to the keypad terminals as an option. 
Only code number 0 - master code is programmed from factory, the other access codes are blank. 

  

[

] [6] [INSTALLER CODE] - Entering of INSTALLER PROGRAMMING LEVEL

. The 

control panel H-915 is completely programmable from the keypad by using commands which are described in detail in 
the installer programming section of this manual. 
 

[

] [8] [MASTER CODE]

 - Entering of 

zone 1 to 6 bypassing

. A bypassed zone will not cause an 

alarm. If a zone is bypassed, the panel may be armed even if the zone is triggered. Use bypassing when access is 
needed to part of the protected area. Also damaged wiring or contacts on a zone may be temporarily bypassed until 
repairs can be made.  To bypass zones, enter [

] [8] [MASTER CODE] and the zone number(s) to be bypassed. 

Press 

[#] to return back to standby

 mode. Remember, if no keypad entry is made for more than 1 minute the system will 

return to the standby mode automatically. The ERROR LED will blink rapidly while you are in zone bypassing mode. 
The zone LEDs which are blinking, while  bypassing is selected, indicate the bypassed zones. By pressing a number key 
(from 1 to 6) you can "switch ON - OFF - ON ..." the bypass of the corresponding zone.  When you are arming the H-915 
and bypass of any zone(s) is set, you will see the corresponding zone LEDs blinking during exit delay. This way, the 
keypad informs you of which zone(s) were switched off.  The Bypass setting is only valid for one arming period. Zone 
bypasses are automatically canceled when the panel is disarmed.  
 

[

] [9] [access code] - AT HOME arming

. Entering [

] [9] before the arming code arms the panel without 

any exit delay in the delay zones and bypass zones that are defined as "INTERIOR". When the panel is AT HOME 
armed, the color of the ARM LED light is green.  

NOTE: If quick arming feature was enabled in the installer programming level, press only [

] [9] for AT HOME arming. 

 

AUTO AT HOME ARMING

 - if this function is enabled in the installer programming level (section [4]), the system is 

able to recognize automatically if you are at home or not. 
 If a correct access code is entered for arming, the green ARM LED will flash slowly. The system expects that you will 
stay at home and it is ready for AT HOME arming after the exit delay. If you trigger a delay zone during the exit delay (for 
example with magnetic sensor on the entrance door), the light of the ARM LED turns  yellow  and the system will be fully 
armed. 

Summary of Contents for HESTIA H-915C

Page 1: ...Security Alarm Control Panel HESTIA 915 installation manual ...

Page 2: ...uired 12V from 1 2Ah to 40Ah stand by consumption 25mA back up power output 12V max 500mA inputs eight loops FIRE TAMPER and 6 fully programmable loops type of loops balanced with End Of Line resistor 10k remote control inputs digital bus for external keypads programmable optional pulse input outputs overswitching relay contact 1A at 60 V external siren output 0 5A at 12 V backup siren output BS f...

Page 3: ...nput is also triggered if normally closed contacts wired in series with EOL resistor are opened see the wiring diagram The Fire alarm is activated if a detector connected to a FIRE input is triggered The Tamper alarm can be triggered either by the built in tamper switch control panel keypads or by the tamper switches connected to the TAMP input The definition of zone 1 to 6 delay instant 24hr fire...

Page 4: ... 5 can be used connect all of them in parallel Check carefully that you have connected corresponding wires before you turn on the power to the control panel The built in keypad on the H 915C model is connected via INT KEY connector Control panel TAMPER There is a tamper switch to protect the housing of the control panel If you have only the H 915B main board don t forget to install the attached ta...

Page 5: ...on was enabled in the installer programming level If quick arming is enabled the H 915 can be AT HOME armed by entering only the 9 command DISARMING Enter a valid access code to disarm If the chime jumper in the H 915K keypad is connected and you triggered a sensor in a delay zone the keypad buzzer will be beeping In such a case you have only a limited amount of time entrance delay to enter a vali...

Page 6: ...atically in the moment when used once for arming NOTE If you press 9 in user programming level the H 915 control panel will send information about events history to the special serial interface printer which can be connected to the keypad terminals as an option Only code number 0 master code is programmed from factory the other access codes are blank 6 INSTALLER CODE Entering of INSTALLER PROGRAMM...

Page 7: ...If the premises is entered without coming through a delay entrance and a next delay loop is triggered an immediate intruder alarm will be generated 05 24Hr silent loop operates as the type 01 but it triggers the PANIC alarm 06 Instant silent loop operates as the type 02 but it triggers the PANIC alarm 07 Delay silent loop operates as the type 03 but it triggers the PANIC alarm 08 Interior instant ...

Page 8: ...rmed by both sirens The y can only be from 0 to 3 4 1y External arming control with loop 6 input If y 0 zone input 6 will work as programmed in section 1 If y 1 than zone input works as input for external arming and disarming If you close this input with E O L resistor for a moment it will have the same function as entering of a valid access code By doing this the control panel can be armed disarm...

Page 9: ...l will start in the alarm condition when the power is switch on again If there is any reason to switch the power completely off for example when you want to extend the system with an optional device we recommend to enter the installer programming level at first FACTORY DEFAULT SETTING Master Code 1234 Installer Code 1010 No other access codes programmed Zone definition 1 delay 2 next delay interio...

Page 10: ...F 3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON For Panic alarm y can only be 0 or 2 Panic alarm always activates Panic o Fire alarm aiways activates Fire out ES Ext Siren IS Int Siren 3 xy Alarm outputs definition x alarm default otputs programmed enter y 0 technic Relay 3 0 _ 1 fire ES IS Relay Fire 3 1 _ 2 intruder ES IS Relay 3 2 _ 3 panic Panic 3 3 _ 4 xy System option functions...

Page 11: ...USER S OPERATION GUIDE OF H 915 Zone location No protected area zone type 1 2 3 4 5 6 Tamper Fire Exit Entry Alarm if troubles call your installer phone H 915 installation manual 11 11 TBT502 01 ...

Page 12: ...H 915 installation manual 11 12 TBT502 01 ...

Reviews: