- 15 -
MLO51206
Unsetting Azor
−
Press the UNSET button on the RFID tag reader (A) and scan the RFID tag (B)
−
The green LED indicator lights up and the reader confirms its unsetting (2 beeps).
Tips and specifications
The system can also be unset via the telephone voice menu.
If you activate a detector prior to unsetting (e.g. when you open the door) a warning tone is
sounded and then AZOR waits silently for unsetting for 30 seconds. If the system is not unset in
time, an alarm is triggered.
If you press the RFID tag reader button in the unset state, a green LED indicator lights up.
If three beeps are sounded during unsetting, there has been an alarm when you were not
present.
In the event of unauthorized manipulation of some of the parts of the system in an unset state a
warning beep is sounded and an SMS tamper report is sent. The SMS report is sent only on the
first occasion of tampering with the device.
If the users have enabled SMS reporting when the system is being set, no report will be sent to
them if they set the system themselves by their own remote control or RFID tag. The RFID tag
corresponding to the user (its phone number) must be used.
Alarm
When an alarm is triggered, the system informs the ARC immediately*. It concurrently
activates a siren, sends alarm SMS messages to users and subsequently calls the users.
An alarm can be cancelled
by pressing the UNSET button on the reader and scanning a
RFID tag, or by using a telephone and the voice menu.
Tips and specifications
If you receive an alarm call, Azor will not call the other users. If no one receives the alarm call,
Azor tries to call all the users once more.
If you do not cancel the alarm, the siren sounds for 3 minutes and then switches off. Azor keeps
guarding.
If an identical detector triggers an alarm three times in a row (e.g. when you forget to close
a window and the wind moves a curtain in front of the detector), such a detector is bypassed
and other detectors keep guarding. A bypassed detector will be included again by unsetting.
A tamper alarm (unauthorized handling of a detector or GSM control unit) is sent just once.
Besides alarm information, Azor also sends SMS reports when it is switched off or if there
is a failure (e.g. power supply failure exceeding half an hour, low battery in a detector,
communication loss to a detector or RFID tag reader, etc.).
* If guarding by an ARC is arranged
Summary of Contents for Azor
Page 1: ...MLO51205 1...
Page 6: ...MLO51206 6 AZ 10P motion detector Reports human motion...
Page 25: ...25 MLO51206...