Aircraft Technical Manual
Jabiru Aircraft
Pty Ltd
J120, J160, J170, J200/J400, J230/J430, J250/J450 Variants
This document is controlled while it remains on the Jabiru server. Once this no longer applies the document becomes uncontrolled.
ISSUE
1
2
3
4
5
Dated: 29th October 2014
Issued By: AS
Page: 48 of 298
Annual Inspection
Each 200 Hours
Each 100 Hours
10
Control horns, hinges & hinge lock tabs.
*
*
*
11
Aileron controls & linkages
*
*
*
12
Rigging check flight
*
13
Throttle controls
*
14
Control Surfaces per Section 5.18
*
*
** Note that the control clearance inspection detailed in Section 5.18 must also be carried out at any time
when the control rigging may have been altered
– i.e. if a control is removed, repaired or adjusted.
5.5
Servicing
Servicing requirements are shown in Section 5.4 below. The following paragraphs supplement this
table by adding details not included.
Note: Inspection Requirements are detailed at Paragraph 3.5.
5.5.1 Engine Servicing Schedule
5.5.1.1 Pre-Flight:
Refer to Flight Manual
5.5.1.2 Other Servicing
Refer to Engine Maintenance Manual
5.6
General Inspection Guidelines
As all possible circumstances cannot be listed here, the following is provided as guidance only. A
critical, trained eye is required and inspections should include, but not be limited to, the following.
MOVING PARTS:
Check for: lubrication, servicing, security of attachments, binding, excessive wear,
safety, proper operation, proper adjustment, correct travel, cracked fittings, security of hinges,
defective bearings, cleanliness, corrosion, deformation, sealing and tension.
METAL PARTS:
Check for: security of attachment, cracks, metal distortion, broken welds, corrosion,
and any other apparent damage.
WIRING:
Check for security, chafing, burning, defective insulation, loose or broken terminals, heat
deterioration and corroded terminals.
BOLTS IN CRITICAL AREAS:
Correct torque in accordance with torque values given in the chart in
Section 2.19, when installed or when visual inspection indicates the need for a torque check.
NOTE: Torque values listed are for oil-free cadmium-plated threads and are recommended for all
installation procedures contained in this manual except where other values are stipulated. They
are not to be used for checking tightness of installed parts during service.
FILTERS, SCREENS and FLUIDS:
Cleanliness, contamination and/or replacement at specified
intervals.