J. K. Medico CCC405 Instructions Manual Download Page 4

Battery care 

 

To get the most out of the batteries with regard to operating time per charge and total lifetime, observe the 
following: 

 

Always turn the wheelchair off when not in use. 

o

 

If the wheelchair is left on, this may cause significant depletion of the battery. 

o

 

Significant depletion will reduce the lifetime of the battery unless it is recharged immediately. 

Recharge daily (every night, if possible) - even if the full capacity of the battery has not been used. 

o

 

The charger cannot overcharge the battery. 

Always recharge the battery as soon as possible after it has gone flat. 

 
 

Meaning of the flash codes 

 

 

 

Stage on 

start-up 

  

 

 

All lights lit for around 1 second during start-up test 

 

 

  

From 1 to 15 short flashes on CHARGING depending on charging characteristics (set before 
delivery)  

  
  
  
  
  
  
  
  

4 flashes that signal the charger's properties (set before delivery): 
  
1st flash: TCS additional charging (patented). 
2nd flash: Temperature-compensated standby charging. 
3rd flash: Charging of batteries with off-load voltage below 16.8V possible. 
4th flash: Ampere-hour meter. 
  

Red

 flash (ERROR light):               Property 

passive

 

Green

 flash (COMPLETED light):  Property 

active

 

 
 
Figure 1: Signaling of the charger's configuration when the charger is on. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

 

3

Summary of Contents for CCC405

Page 1: ...in wheelchairs and scooters Certified to EN60601 1 3rd ed in accordance with the EU Directive 93 42 EEC on medical devices Splash proof dustproof and water proof IP54 IP65 and IP67 WWW JK Medico DK Te...

Page 2: ...e charger off by removing the charger s power plug from the outlet 6 If it becomes necessary to interrupt charging before the COMPLETED light comes on turn the charger off by removing its power plug f...

Page 3: ...ars although at least 4 hours before connecting the charger to the mains power or the wheelchair Warning For safety reasons batteries must not be repeatedly recharged if the charger has reported that...

Page 4: ...ry Always recharge the battery as soon as possible after it has gone flat Meaning of the flash codes Stage on start up 1 All lights lit for around 1 second during start up test 2 From 1 to 15 short fl...

Page 5: ...pacity Contact battery supplier 3 4 OFF ON 5 flashes Battery fault Battery voltage too high System fault 2 External error source Group flash with ERROR OFF OFF 6 flashes Charger temperature too high C...

Page 6: ...isplay showing charged capacity when the charging plug is removed from the wheelchair s charging socket once charging has ended Number of yellow flashes Number of green flashes Charged capacity ampere...

Page 7: ...ing The charger may only be used for wheelchairs if the mains supply is designed for a current that corresponds to at least the charger s specified charging current There must be a fuse suitable for u...

Page 8: ...the charger so that the distance to the wheelchair is at least 20 cm Do not place the charger in direct sunlight by radiators or any other heat source Important Avoid covering the charger in any way...

Reviews: