Installation Instructions:
Determine location to mount unit
(“
DANGER
” “
THIS EQUIPMENT
INCORPORATES PARTS SUCH AS SWITCHES, MOTORS, OR THE
LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN
CAUSE AN EXPLOSION. WHEN LOCATED IN GASOLINE-
DISPENSING AND SERVICE STATIONS INSTALL AND USE AT
LEAST 20 FEET (6 M) HORIZONTALLY FROM THE EXTERIOR
ENCLOSURE OF ANY DISPENSING PUMP AND AT LEAST 18
INCHES (450 MM) ABOVE A DRIVEWAY OR GROUND LEVEL.”
Run 20 amp service to specified location. Grounding Instructions: This
appliance must be connected to a grounded metal, permanent wiring
system; or an equipment-grounding conductor must be run with the
circuit conductors and connected to the equipment-grounding terminal or
lead on the appliance.
Unit must be mounted level for proper operation.
Mount unit to location and use fig. 1 for mount pattern
If unit is vault ready configuration see fig. 1 for mounting and fig. 2 for
vault tube location.