J.E. Adams 29000 Series Owner'S Manual Download Page 7

turned off to reactivate. Restart on allows for additional coins to be put in the 

machine to keep unit running. To set use 

VOL –

 or 

VOL +

 to change. 

17)

 

Press the 

CH +

 button. Display will now read 

STD

 or 

USER

 or 

MIX

. To make a 

custom message use 

VOL +

 button to scroll to USER. At this point press and hold 

CH +

 button until original message appears. At this time you may change the 

message simply by using the 

VOL –

 or 

VOL +

 buttons to change letters. 

Once 

message has been entered you must put the symbol / at the end of 

message.

 This will tell display that this is the end of the message. 

18)

 

Press the 

CH +

 button now 5 more times to exit programming. 

19)

 

Unit should now be programmed. 

 

Program definitions: 

 

Bonus time settings: 

¾

 

Amount of time set in bonus time is added to regular time per 
coin/pulse(e.g. if you want to give 45 seconds for bonus time and 

your regular time per coin is 30 seconds, you would set bonus time 

at 00:15) 

¾

 

Bonus is disabled by setting bonus time to 00:00. 

¾

 

If bonus time is set to less than one minute, bonus time is added 
when bonus coin is reached and every coin after that until time 

expires. 

¾

 

If bonus time is set at 1:00 or more, bonus will be a “one time” 

bonus. Bonus time will only be added for bonus coin or multiplies of 

bonus coin (e.g. 16

th

 coin, 32

nd

 coin, etc). Any other coin will on 

receive regular time per coin. 

¾

 

If bonus time is set to 99:00, when bonus coin is deposited, timer 
will show “-on-“ and timer will continue to run until coin switch wire 

is shorted to ground by a loop detector or other switch closure for 

a minimum of two seconds. 

 

 

Debit and credit mode: 

¾

 

Debit mode: As coins are deposited display shows “$1.75 MORE, 

$1.50 MORE, $1.25 MORE” etc. until start price is reaches. Once 

start price is reached display switches to time accumulating until no 
more coins have been deposited. 

¾

 

Credit mode: As coins are deposited display shows money 
accumulating ($.25, $.50, $.75 etc). If timer is also set to delayed 

start mode timer will continue to show money accumulating until 

no more coins have been deposited. If timer is set to instant start, 
as soon as start price is reached, timer will change to time counting 

down. 

¾

 

Both mode: As coins are deposited display shows money 

accumulating ($.25, $.50, $.75 etc). If start price is not reached, 

after 5 seconds timer will alternate between “add $x.xx more” and 
amount of money already deposited.  

 

 

7

Summary of Contents for 29000 Series

Page 1: ...ru 29003 2M o PAGE 2 PRODUCT INFORMATION o PAGE 3 SPECIFICATIONS o PAGE 4 IMPORTANT SAFETY INFORMATION o PAGES 4 5 INSTALLATION o PAGES 5 8 PROGRAMMING o PAGE 8 OPERATING o PAGE 8 MAINTENANCE o PAGES 9 TROUBLESHOOTING o PAGES 10 14 PARTS LIST o PAGE 15 18 WIRE DIAGRAMS REV 5 20 2010 ...

Page 2: ...r can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL _________________________________________ SERIAL _________________________________________ KEY NUMBER S _________________________________ DATE PURCHASED _______________________________ DISTRIBUTOR ___________________________________ ...

Page 3: ...s 29000 2M thru 29003 2M Voltage 120v 60Hz Amperage 1 20 amp service is required for this unit Weight 260 lbs with pallet attached Vac specifications 29000 2M thru 29003 2M Motors 2 120VAC Vacuum motor Fuses 2 10 amp inline fuses Shampoo specifications 29000 2M thru 29003 2M Compressor 1 Thomas 120v 1 12th hp compressor Peristaltic pump 2 Thomas peristaltic pumps 12VDC NOTE UNIT INTENDED FOR COMME...

Page 4: ...as cigarettes matches or hot ashes DO not use without dust bag and or filters in place SAVE THESE INSTRUCTIONS Installation Instructions Determine location to mount unit DANGER THIS EQUIPMENT INCORPORATES PARTS SUCH AS SWITCHES MOTORS OR THE LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN CAUSE AN EXPLOSION WHEN LOCATED IN GASOLINE DISPENSING AND SERVICE STATIONS INSTALL AND USE AT LEAST 20 FEET...

Page 5: ... power insert shampoo and spot formula into bottom door and attach lids to appropriate bottles Turn unit on and move to program instructions Programming Instructions Coin acceptor No programming to acceptor needed if unit was purchased with the standard Imomex Z32 electronic acceptor 8149 92 our part number is pre programmed to accept US quarters 984 tokens US 1 coin and 1 073 token Acceptor is pr...

Page 6: ... to decrease or the VOL to increase Once time is entered move to next step 7 Press the CH button Display will now read C 30 or may be different time C Will be the time per coin for SHAMPOO Set desired time per coin by using the VOL to decrease or the VOL to increase Once time is entered move to next step 8 Press the CH button Display will now read D D is not used 9 Press the CH button Display will...

Page 7: ...ery coin after that until time expires If bonus time is set at 1 00 or more bonus will be a one time bonus Bonus time will only be added for bonus coin or multiplies of bonus coin e g 16th coin 32nd coin etc Any other coin will on receive regular time per coin If bonus time is set to 99 00 when bonus coin is deposited timer will show on and timer will continue to run until coin switch wire is shor...

Page 8: ...n credit card is selected swipe card and wait for activation If shampoo spot is selected it is recommended that you vacuum before applying formula If other function is selected other than original selected item unit will recalculate timer based on the amount of money it takes to start the specific function Once service is used hang up hose Changing fluids Disconnect power Unscrew cap from empty bo...

Page 9: ...ied to machine Call electrician and install proper wire size for 30amp service versus length or run Wrong size breaker Install correct breaker only use wire size that is adequate to handle 30 amp breaker Fuses for vac motors keep blowing Inadequate wire size supplied to machine Call electrician and install proper wire size for 30amp service versus length or run Motor brushes may be bad or too shor...