5.  Insert the lamp back into the quartz sleeve until the spring resists further

travel.  Gently  push  down  and  twist  the  lamp  connector  a  quarter  turn
clockwise  - the bayonet fitting will hold the lamp holder in place.

6.  Insert the lamp key into the ballast controller.

7. 

Reconnect the earth wire to the chamber tab.

www.jdultrasonics.co.uk    

  +44 (0)1924 378 448

UV DISINFECTION - OPERATING & MAINTENANCE

INITIATE LAMP COUNTDOWN SEQUENCE

After changing the lamp on the system, the controller
must  be  reset  in  order  for  the  system  to  begin  its
countdown  function  on  a  newly  installed  lamp.  To
perform  this  reset,  firmly  depress  the  button  on  the
front of the controller and then manually power up the
unit.

Keep holding down the button for five seconds until the
controller  has  reset  the  internal  timer.  Release  the
button and the lamp countdown feature has now been
reset.  An  audible  chirp  will  be  heard  as  well  as  the
“lamp life reset” screen.

Atlas UV

Atlas UV

Atlas UV

lamp life reset

continue holding

button to reset

lamp timer

5s

screens during reset

2

1

sonicom™

J D UltraSonics