background image

 

12

CLEARANCES 

 
Due to its reduced clearances, this appliance occupies a minimum of space in the room 

where it is installed. No matter where you install it, this appliance will perfectly complete 
your  decoration  by  its  originality  and  its  heat.  This  appliance  only  needs  8  inches 
clearance at its back and 12 inches from the lateral walls when installed with a single wall 
pipe and a certified CAN/ULC S641 heat shield. 
 

 
 
 

 

C

LEARANCES FROM COMBUSTIBLE MATERIALS

 

(Measured from the top of the appliance) 

Single wall pipe 

Single wall pipe with certified 

Can/ULC S 641 heat shield  at the 

back 

Inches 

Centimeters 

Inches 

Centimeters 

18 

45.7 

20.3 

12 

30.5 

12 

30.5 

20.5 

52.0 

10.5 

26.7 

22 

55.9 

22 

55.9 

 

     A 

Summary of Contents for Mystere

Page 1: ...NUAL MYSTERE WITH OR WITHOUT OVEN March 9th 2009 Reviewed MYSTERE wood burning stove 490 rue de l Argon Quebec Qc CANADA Qu bec G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com CAN ULC S627...

Page 2: ...INSIDE A MASONRY CHIMNEY 9 EXTERIOR VERTICAL INSTALLATION 9 VERTICAL INSTALLATION ON A CATHEDRAL ROOF 10 CROSS STYLE INSTALLATION 10 VERTICAL INSTALLATION 11 CLEARANCES 12 SEATING 13 FIREBRICKS 13 FAN...

Page 3: ...IFIED TECHNICIAN AND IN CONFORMITY WITH THE OWNER S MANUAL GUIDE GIVEN WITH THIS APPLIANCE THE INSTALLATION MUST BE IN AGREEMENT WITH LOCAL AND NATIONAL REGULATIONS APPLICABLE FOR SOLID FUEL BURNING A...

Page 4: ...a minimum of 64 ft2 and must be very well ventilated Minimum clearances found in this manual must be observed Never use a non isolated exterior conduct or a single wall flue pipe as an exterior exit P...

Page 5: ...e knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire Hermetically close the doors and the air intakes Water the combustible materi...

Page 6: ...light smoke is released from the paint during the first hours of use Even if this nuisance is temporary open the windows and the doors in order to ensure a good ventilation This special paint is conce...

Page 7: ...7m Exterior height 46 116 8cm 31 78 7cm Exterior width 26 66cm 26 66cm Exterior depth 27 70 5cm 27 70 5cm Door opening 17 X 9 44 5cm X 24 1cm 17 X 9 44 5cm X 24 1cm Interior height 12 30 5cm 12 30 5cm...

Page 8: ...e heat loss with an insulated lining The chimney has to be installed with a stainless steel lining Make sure that all smoke pipe joints are really airtight A leak reduces the efficiency of the applian...

Page 9: ...l laws or the ULC S635 ULC S640 NFPA211 USA norms Install the chimney following the manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The Mystere wood appliance must be installed in accordanc...

Page 10: ...ocal laws or the CAN CSA B365 NFPA211 USA norms Install the chimney following the manufacturer s instructions CROSS STYLE INSTALLATION The Mystere wood appliance must be installed in accordance with t...

Page 11: ...ICAL INSTALLATION The Mystere wood appliance must be installed in accordance with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Install the chimney following the manufacturer s instr...

Page 12: ...ance only needs 8 inches clearance at its back and 12 inches from the lateral walls when installed with a single wall pipe and a certified CAN ULC S641 heat shield CLEARANCES FROM COMBUSTIBLE MATERIAL...

Page 13: ...hes at the back Use only non combustible materials such as ceramics marble or granite FIREBRICKS Place the firebricks as illustrated They are identified by the letters A to H and the seal cap is ident...

Page 14: ...liance is in function the heat reaching a temperature of 120oF activates the thermo disc At this moment the thermo disc activates the fans for a better distribution of heat in your home As soon as the...

Page 15: ...nce until you know at which frequency it must be cleaned minimum once per year Remove every creosote deposit in order to prevent chimney fires The cleaning of the heat exchanger of the chimney flue pi...

Page 16: ...eal cords are damaged If so replace them by a inch ceramics cord and replace the broken glasses by VITROCERAMICS glasses of 5mm Cut the glass edge 3mm smaller on each side so that the asbestos cord ca...

Page 17: ...urer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with res...