iZone C110MC Installation And User Manual Download Page 7

3.1 & 3.2 Set up number of zones & electronic constants required 

As an example the diagram shows 4 

ac!ve zones 

C110MC 

——  

Zone 1 —— 

Zone 2 —— 

Zone 5 —— 

Zone 3 —— 

Zone 4 —— 

Zone 6 —— 

C

T

2

4

A

C

 —

 

 C

1

1

0

W

C

 

 C

1

1

0

W

C

 

N29007 

Installation Instructions 

 

1. Connect Zone Damper Actuators (CZDA) to the Zone ports 

using the RJ11 cables. 

 

2. Connect the Wall Controllers (C110WC) to the ports using 

the Blue RJ45 cables.  

 

3. Select the number of active zones required on the dip 

switch. 

 

4. Select the number of electronic constant zones required. 

 

5. Connect the power supply to the(CT24AC) port. 

1

 

2

 

3

 

4

 

5

 

6

 

O

N

 

—— 1 
—— 0 

—— 2 

Electronic 
Constant  Zones 
required 

Active 
Zones 

Set number of zones  on the dipswitch 

on the side of the C110MC box 

Set number of electronic constant zones 

required on switch on the side of the 

C110MC box 

As an example  the switch is shown 

selec!ng 1 electronic constant   

Summary of Contents for C110MC

Page 1: ...110 Zone Controller Installation and User Manual...

Page 2: ...2 Installation instructions 4 2 0 System initialisation 5 3 0 System configuration 6 3 1 Set the number of zones required 6 7 3 2 Set the number of electronic constants required 6 7 3 3 Testing and L...

Page 3: ...110MC iZone 110 Master Controller CZDA Zone 3 Zone 2 Zone 4 Zone 6 Zone 5 CT24AC 6 Zone system with 2 wall controllers shown A maximum of 6 zones and 2 wall controllers can be supported by one iZone 1...

Page 4: ...consecutive ports starting at Zone 1 The back of the C110MC is marked with the zone port numbers 5 Do not directly hardwire the CT24AC into the AC unit s power supply This may void the warranty as it...

Page 5: ...e of any wall controller This button is recessed so you will need to use a pen to press the button The time to initialise the system will vary depending on the number of motors connected The system wi...

Page 6: ...system An electronic constant is a safety feature and ensures that a predetermined number of zones remain open at all times even if all the zones are switched off If 1 electronic constant is selected...

Page 7: ...rollers C110WC to the ports using the Blue RJ45 cables 3 Select the number of active zones required on the dip switch 4 Select the number of electronic constant zones required 5 Connect the power supp...

Page 8: ...Master Bed Bedroom 1 8 3 3 Testing and Labelling Label the zone accordingly Switch all zones OFF and one zone ON Check which zone is being supplied with air...

Page 9: ...Master Bed Lounge Kitchen Family Guest Bedroom 1 4 0 User manual 9 Press the silicone bu on to switch zones on and o The LED will illuminate when the zone is on...

Page 10: ...system or iZone system you should contact your installation company 2 If you want to add more zones you should contact your installation company 3 If your require assistance operating your iZone conta...

Reviews: