iZone C110MC Installation And User Manual Download Page 4

1.2 Installation instructions  

1. 

The C110MC can be installed on top of the indoor fan coil unit. 

2. 

Do not run the blue network cables alongside 240 Volt wiring. 

3. 

When installing network cables down wall cavities or chasing network cables into walls, tape up and protect the RJ45 connector to avoid 
damage to the connectors. 

4. 

Always install zones in consecutive ports starting at Zone 1. The back of the C110MC is marked with the zone port numbers. 

5. 

Do not directly hardwire the CT24AC into the AC unit’s power supply. This may void the warranty as it will require an electrician in the 
event that repair of the iZone 110 system is required. 

6. 

Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ11 cables as shown. 

7. 

Connect the Wall controller(s) (C110WC) to the C110WC ports using the RJ45 cables.  

8. 

Only connect the power supply to the CT24AC port after all components have been connected.  

 

Summary of Contents for C110MC

Page 1: ...110 Zone Controller Installation and User Manual...

Page 2: ...2 Installation instructions 4 2 0 System initialisation 5 3 0 System configuration 6 3 1 Set the number of zones required 6 7 3 2 Set the number of electronic constants required 6 7 3 3 Testing and L...

Page 3: ...110MC iZone 110 Master Controller CZDA Zone 3 Zone 2 Zone 4 Zone 6 Zone 5 CT24AC 6 Zone system with 2 wall controllers shown A maximum of 6 zones and 2 wall controllers can be supported by one iZone 1...

Page 4: ...consecutive ports starting at Zone 1 The back of the C110MC is marked with the zone port numbers 5 Do not directly hardwire the CT24AC into the AC unit s power supply This may void the warranty as it...

Page 5: ...e of any wall controller This button is recessed so you will need to use a pen to press the button The time to initialise the system will vary depending on the number of motors connected The system wi...

Page 6: ...system An electronic constant is a safety feature and ensures that a predetermined number of zones remain open at all times even if all the zones are switched off If 1 electronic constant is selected...

Page 7: ...rollers C110WC to the ports using the Blue RJ45 cables 3 Select the number of active zones required on the dip switch 4 Select the number of electronic constant zones required 5 Connect the power supp...

Page 8: ...Master Bed Bedroom 1 8 3 3 Testing and Labelling Label the zone accordingly Switch all zones OFF and one zone ON Check which zone is being supplied with air...

Page 9: ...Master Bed Lounge Kitchen Family Guest Bedroom 1 4 0 User manual 9 Press the silicone bu on to switch zones on and o The LED will illuminate when the zone is on...

Page 10: ...system or iZone system you should contact your installation company 2 If you want to add more zones you should contact your installation company 3 If your require assistance operating your iZone conta...

Reviews: