Appendix B – Default settings
The default settings of the jumpers of the PC-I 04 are listed in the following. With
special versions of the interface, individual settings may vary.
Basic address: D000h A17 ON
A16 OFF
A15 ON
A14 ON
A13 ON
A12 ON
A11 ON
A10 ON
Interrupt CAN 1: IRQ 5
Interrupt CAN 2: IRQ 7 (only if assembled)
Interrupt mode CAN line 1: JP12 1-2 & JP15 2-3 (ISA mode)
Interrupt mode CAN line 2: JP13 1-2 & JP21 2-3 (ISA mode)
Appendix C – Sources of data sheets
CAN controller Philips SJA1000:
www.semiconductors.philips.com
CAN transceiver Texas Instruments SN65HVD251:
www.ti.com
PC/104 specification:
www.pc104.org