Oceano HD100 Lift - User Guide
System:
HD100
Preventive Maintenance
Sub-system
:
Reference:
PM03
Page:
1/2
Subject: Changing Batteries of the
AR861S
Maintenance level:
Periodicity:
Duration:
Caution
B
ATTERY CELL VOLTAGE SHALL NEVER DROP BELOW
7
V.
A
FTER A LONG STANDSTILL PERIOD OF THE UNIT
,
IT IS RECOMMENDED TO INSTALL NEW BATTERY
PACKS
.
Remove the acoustic actuator from the frame. Refer to PM01 step 3.
Remove
Actuator
Opening
Step Action
1.
Set the acoustic actuator horizontally.
2.
Using a “ Allen ” hexagonal key size 10, remove the screw (ref.: 910 1388) on the
opposite side of the acoustic head. Hold the head during operation (dropping hazard).
3.
Extract the acoustic head. Disconnect the connector.
4.
Extract the other part (on releasing side). The electronic equipment and battery packs
are directly secured on this cover.
1.
Remove the three M3 screws of the battery circuit (fixing of the printed circuit board).
2.
Remove the three battery packs (3 packs of six R20 alkaline batteries), either by
inclining the unit to slide the batteries out, or by pulling them. The batteries are soldered
together to overcome the effects of high impact loads during some launching operations.
3.
Replace with new ones, individually tested, and respect their polarity.
4.
Secure the battery connection printed circuit board.
5.
End of procedure.
Replacing
Batteries
MU – HD100L – AN – 001 - Ed A – January 2010