All appliances must be mounted so that the lowest
point is at least 2.2m above the floor. The Vent
body and ducted blower is designed to fit a ceiling
cavity or between – floor space with a minimum
height of 245 mm. The modules may be installed
between joists using the spring clips (Fig. 2c).
Ensure that the outlet of the Vent unit is directed
towards the outer wall. If the desired orientation of
the Vent unit directs the ducting across ceiling joists
ensure that the closest ceiling joist is not within
150 mm of the Vent outlet.
Figure 2a - Minimum Blower Clearances
Figure 2b - Minimum Unit Clearances
Figure 2c
C:
Models: 34401, 34402, 35401 & 35402-50 mm
Models: 36411 & 36412 - 75 mm
D:
Models: 34401, 34402, 35401 & 35402-195 mm
Models: 36111 & 36112 - 151 mm
E:
Models: 34401, 34402, 35401 & 35402-35 mm
to structural member
Models: 36411 & 36412 - 50mm to
structural members.
F:
Models: 34401, 34402, 35401 & 35402-150 mm.
Models: 34401, 34402, 35401 & 35402-35 mm
min.clearance is required near all joists
Models: 36411 & 36412-50 mm min.
clearance is required near all joists
.
Fig. 2b: Minimum clearances for installation
Fig. 2c: Minimum clearances for installation
Overview
Electrical Requirements
Fig. 6: Wiring diagram for models 34401 and 34402, Luminate Vent & Light
Modules may be connected to a lighting or power circuit if loading permits. These models are for
wired-in installation and wiring must be carried out by a registered electrician. Switches and a
wall plate are not provided with the Vent & Heat Luminate modules. Do not use these products
with any solid state speed control or commercial dimming device.
Luminate Vent & Light module is fitted with a custom LED panel.
For Luminate modules fitted with LED centre lamps. To ensure
correct operation and to prolong the life of the LEDs please wire as
per the following wiring diagrams for the appropriate model.
Wiring Diagr ams
Fig. 8: Wiring diagram for model 36411 and 36412, Luminate Heat.
Wiring – Aust & NZ
For the heat module (models 36411, 36412) a local isolating switch (not supplied) must be
incorporated in the fixed wiring to the appliance to allow disconnection of supply during
maintenance. A local isolating switch (not supplied) must be incorporated in the fixed wiring
to the appliance to allow disconnection of supply during maintenance.
The Tastic Luminate is classified as a Room Heater and as such:
In accordance to AS/NZS 3000 this isolating switch shall be -
(a) installed immediately adjacent to an entrance to, or within, the room where the room heater
is located; or
(b) installed on the switchboard at which the room heater final subcircuit originates.
Refer to AS/NZS 3000 for further regulations regarding isolating devices.
It must not be installed where it can be reached from the bath or shower recess or enclosure
(see AS/NZS 3000 Section 7).
Vent & Vent & Light models 34401, 34402, 35401 & 35402:
Switch the power outlet for the Inline Blower with a wall switch (not supplied with Vent Module)
as per the Wiring Diagrams. Do not mount the power outlet for the Inline Blower more than 200 mm
from the Inline Blower.
Fig. 7: Wiring diagram for model 35401 and 35402, Luminate Vent
E
35401 & 35402: 0.3A 50Hz
M
DUCTED FAN
ACTIVE
NEUTRAL
36411 & 36412: 3.3A 50Hz
BODY
ACTIVE
NEUTRAL
TERMINAL BLOCK
THERMAL SWITCH 65°C
HEAT L AMP
Wiring Diagr ams
Fig. 4: Layout of Luminate Vent & Light
Neo Models: 34401, 34402, 35401, 35402
Wall switch (not supplied)
Inline Ducted Blower
Ducting
Air outlet grille
positioned in eaves lining
Exterior
of home
Eaves
lining
Vent unit
Flexible support
Vent & Light Cable
Wall Switch (not supplied)
Wall Switch (not supplied)
Recommended Ceiling Heights
Minimum ceiling height for all models Tastic
Luminate is 2.2m.
Ensure that the exhaust outlet of the Tastic is
directed towards the outer wall.
For maximum efficiency and fan performance
there are a few key points to
keep in mind when installing your Tastic.
Sufficient air inlet into room
Steam will only be removed if there is sufficient
flow of air through the room.
Ensure generous inlets exist through windows,
vents or under the door.
Airflow path from inlet to fan should ideally
pass over the steam sources (see Fig.1)
Bathrooms which have high ceilings, are larger
then average, or have an open
shower may all require an additional ventilation
fan to be installed.
We recommend that you visit our website for
further details and suggestions on
effectively ventilating your bathroom.
Clearances
Ventilation Requirements
Fig. 2a: Minimum blower clearances
215
mm
Blower
Height
min.
overall
height
230mm
15mm clearance above unit
Fig.1: Ideal placement of Tastic.
Min
300mm
Min
1500mm
Wall
Wall
Min
300mm
Sprinkler System / Smoke Detector
Fig 3. Clearance to walls
Luminate Heat Module Clearances
Safety
Safety Features
Thermal Switch (Heat Module only)
When for any reason the temperature inside the unit reaches 65°C, the thermal switch will cut off
power to the Tastic Luminate. When the temperature drops, the thermal switch will automatically reset
and reconnect the power.
Do not look directly into heat lamps when in use.
Tastic products are not tanning lamps.
Make sure the lamps have cooled and power is off to the Tastic before removing lamps for replacement.
Do not operate this appliance without the fascia or glass panels in position.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Young children should be supervised to ensure they do not play with the appliance.
This appliance must be mounted with the lowest point at least 2.2 metres from the floor.
If the supply cord is damaged, it should be replaced by the IXL Home or its service agent or a
similarly qualifed person in order to avoid a hazard.
This appliance must not be mounted immediately below a socket outlet.
Regulations concerning the discharge of air have to be fulfilled.
WARNING:
Curtains or combustible material may ignite if in contact or close proximity with the heater.
NOTE:
This product must be installed by a qualified installer.
Locate the Tastic in accordance with the requirements of the current Australian/New Zealand Wiring
Rules AS/NZS 3000 relating to damp situations.
In some installations this may mean that no part of these Tastic may be located directly above any part
of a bath or shower recess or enclosure. For unenclosed showers refer to Wiring Rules conditions.
Switches and other controls must not be located where they can be touched by a person in the bath
or shower.
Read through these instructions completely before commencing installation.
When installed, the Tastic Luminate appliance shall, under no
circumstance, be covered with insulating material or similiar material.
This Tastic unit must be installed horizontally in the ceiling.
There is no IP rating on the Luminate Heat module. Vent and Vent
& Light modules have IPX4 rating.
To prevent overheating do not place any object within 1 metre
of heat lamps.
Luminate Vent Area Suitability:
8.3m
2
with shower / 20.8m
2
without shower
Based on standard 2.4m ceiling height
Luminate Vent & Light Area Suitability:
8.3m
2
with shower / 20.8m
2
without shower
Exhaust Fan Capacity
400m
3
/hr
Recommended Room Size