All appliances must be mounted so that the lowest 
point is at least 2.2m above the floor. The Vent 
body and ducted blower is designed to fit a ceiling 
cavity or between – floor space with a minimum 
height of 245 mm. The modules may be installed 
between joists using the spring clips (Fig. 2c). 
Ensure that the outlet of the Vent unit is directed 
towards the outer wall. If the desired orientation of 
the Vent unit directs the ducting across ceiling joists 
ensure that the closest ceiling joist is not within 
150 mm of the Vent outlet. 

Figure 2a - Minimum Blower Clearances
Figure 2b - Minimum Unit Clearances

Figure 2c

C:

 Models: 34401, 34402, 35401 & 35402-50 mm     

Models: 36411 & 36412 - 75 mm

D:

 Models: 34401, 34402, 35401 & 35402-195 mm      

Models: 36111 & 36112 - 151 mm

E:

 Models: 34401, 34402, 35401 & 35402-35 mm 

to structural member     
Models: 36411 & 36412 - 50mm to 
structural members.

F:

 Models: 34401, 34402, 35401 & 35402-150 mm.

Models:  34401, 34402, 35401 & 35402-35 mm 
min.clearance is required near all joists
Models: 36411 & 36412-50 mm min. 
clearance is required near all joists

.

Fig. 2b: Minimum clearances for installation

Fig. 2c: Minimum clearances for installation

Overview

Electrical Requirements

Fig. 6: Wiring diagram for models 34401 and 34402, Luminate Vent & Light

Modules may be connected to a lighting or power circuit if loading permits. These models are for 
wired-in installation and wiring must be carried out by a registered electrician. Switches and a 
wall plate are not provided with the Vent & Heat Luminate modules. Do not use these products 
with any solid state speed control or commercial dimming device. 

Luminate Vent & Light module is fitted with a custom LED panel.

For Luminate modules fitted with LED centre lamps. To ensure 

correct operation and to prolong the life of the LEDs please wire as 

per the following wiring diagrams for the appropriate model.  

Wiring Diagr ams

Fig. 8: Wiring diagram for model 36411 and 36412, Luminate Heat.

Wiring – Aust & NZ

For the heat module (models 36411, 36412) a local isolating switch (not supplied) must be 
incorporated in the fixed wiring to the appliance to allow disconnection of supply during 
maintenance. A local isolating switch (not supplied) must be incorporated in the fixed wiring 
to the appliance to allow disconnection of supply during maintenance.
The Tastic Luminate is classified as a Room Heater and as such:
In accordance to AS/NZS 3000 this isolating switch shall be - 
(a) installed immediately adjacent to an entrance to, or within, the room where the room heater 
is located; or
(b) installed on the switchboard at which the room heater final subcircuit originates.
Refer to AS/NZS 3000 for further regulations regarding isolating devices.
It must not be installed where it can be reached from the bath or shower recess or enclosure 
(see AS/NZS 3000 Section 7).  

Vent & Vent & Light models 34401, 34402, 35401 & 35402:  

Switch the power outlet for the Inline Blower with a wall switch (not supplied with Vent Module) 
as per the Wiring Diagrams. Do not mount the power outlet for the Inline Blower more than 200 mm 
from the Inline Blower.     

Fig. 7: Wiring diagram for model 35401 and 35402, Luminate Vent 

E

35401 & 35402: 0.3A 50Hz

M

DUCTED FAN

ACTIVE

NEUTRAL

36411 & 36412: 3.3A 50Hz

BODY

ACTIVE

NEUTRAL

TERMINAL BLOCK

THERMAL SWITCH 65°C

HEAT L AMP

Wiring Diagr ams

Fig. 4: Layout of Luminate Vent & Light

Neo Models: 34401, 34402, 35401, 35402

Wall switch (not supplied)

Inline Ducted Blower

Ducting

Air outlet grille 

positioned in eaves lining

Exterior
of home

Eaves 

lining

Vent unit

Flexible support

Vent & Light Cable

Wall Switch (not supplied)

Wall Switch (not supplied)

Recommended Ceiling Heights

Minimum ceiling height for all models Tastic 
Luminate is 2.2m.

 
Ensure that the exhaust outlet of the Tastic is 
directed towards the outer wall.  

For maximum efficiency and fan performance 
there are a few key points to 
keep in mind when installing your Tastic.

Sufficient air inlet into room

Steam will only be removed if there is sufficient 
flow of air through the room.
Ensure generous inlets exist through windows, 
vents or under the door.
Airflow path from inlet to fan should ideally 
pass over the steam sources (see Fig.1)
Bathrooms which have high ceilings, are larger 
then average, or have an open 
shower may all require an additional ventilation 
fan to be installed.

We recommend that you visit our website for 
further details and suggestions on 
effectively ventilating your bathroom. 

Clearances

Ventilation Requirements

Fig. 2a: Minimum blower clearances

215

mm

Blower 

Height  

min. 

overall 

height 

230mm

15mm clearance above unit  

Fig.1: Ideal placement of Tastic. 

Min
300mm

Min

1500mm

Wall

Wall

Min

300mm

Sprinkler System / Smoke Detector

Fig 3. Clearance to walls

Luminate Heat Module Clearances

Safety

Safety Features

Thermal Switch (Heat Module only)

When for any reason the temperature inside the unit reaches 65°C, the thermal switch will cut off 
power to the Tastic Luminate. When the temperature drops, the thermal switch will automatically reset 
and reconnect the power.  

Do not look directly into heat lamps when in use.
Tastic products are not tanning lamps.
Make sure the lamps have cooled and power is off to the Tastic before removing lamps for replacement.
Do not operate this appliance without the fascia or glass panels in position.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety.
Young children should be supervised to ensure they do not play with the appliance.
This appliance must be mounted with the lowest point at least 2.2 metres from the floor.
If the supply cord is damaged, it should be replaced by the IXL Home or its service agent or a 
similarly qualifed person in order to avoid a hazard.
This appliance must not be mounted immediately below a socket outlet.
Regulations concerning the discharge of air have to be fulfilled.   

WARNING: 

 Curtains or combustible material may ignite if in contact or close proximity with the heater.

NOTE: 

This product must be installed by a qualified installer.

Locate the Tastic in accordance with the requirements of the current Australian/New Zealand Wiring 
Rules AS/NZS 3000 relating to damp situations. 
In some installations this may mean that no part of these Tastic may be located directly above any part 
of a bath or shower recess or enclosure. For unenclosed showers refer to Wiring Rules conditions. 
Switches and other controls must not be located where they can be touched by a person in the bath 
or shower.

Read through these instructions completely before commencing installation.

When installed, the Tastic Luminate appliance shall, under no 

circumstance, be covered with insulating material or similiar material. 

This Tastic unit must be installed horizontally in the ceiling. 

There is no IP rating on the Luminate Heat module. Vent and Vent 

& Light modules have IPX4 rating.

To prevent overheating do not place any object within 1 metre 

of heat lamps. 

  

Luminate Vent Area Suitability:

 

8.3m

2

 with shower / 20.8m

2

 without shower

Based on standard 2.4m ceiling height

Luminate Vent & Light Area Suitability:

 

8.3m

2

 with shower / 20.8m

2

 without shower

Exhaust Fan Capacity 

   

400m

3

/hr

Recommended Room Size