Clearances
Tastic
®
All appliances must be mounted so that the lowest
point is at least 2.1 m above the floor. A minimum
clearance of 75 mm for Model 11341 and 90 mm
for Models 12343 & 12341 is required above the top
of the Tastic when installed in a well ventilated roof
cavity. Where ventilation is restricted, this clearance
should be increased by a minimum of 25 mm.
Additionally, a minimum of 15 mm clearance is
required between the two vertical sides of the Tastic
and any adjoining parts of the roof structure, such as
walls, joists or insulation batts.
Figure 3 measurement A
:
Model No 11341
75 mm min. where there is good ventilation to the
sides of the unit.
100 mm min. where ventilation to the sides of the
unit is restricted.
Model No’s 12341 & 12343
90 mm min. where there is good ventilation to the
sides of the unit.
115 mm min. where ventilation to the sides of the
unit is restricted
Figure 3 measurement B
:
Model No 11341
290 mm.
Model No 12341
220 mm
Model No 12343
220 mm.
Figure 3 measurement C
:
15 mm min. clearance on the two vertical sides.
Figure 4 measurement D
:
35 mm min. clearance required when using the
inbuilt clip fasteners.
Fig. 2: Adequate open space in the roof cavity
is required
Fig. 3: Minimum clearances for installation
Fig. 4: Joist clearances
A
D
C
Flaps
Fasten with 2 screws
B