Heat • Vent • Light

Eco Tastic

®

Model: 11341 Eco Triumph 
Model: 12343 Eco Sensation
Model: 12341 Eco Silhouette

 

Electrical Rating: 230~240 V. 50 Hz.

Model: 12341 Eco Silhouette

Model: 12343 Eco Sensation

Model: 11341 Eco Triumph

Summary of Contents for Eco Tastic 12343

Page 1: ...at Vent Light Eco Tastic Model 11341 Eco Triumph Model 12343 Eco Sensation Model 12341 Eco Silhouette Electrical Rating 230 240 V 50 Hz Model 12341 Eco Silhouette Model 12343 Eco Sensation Model 11341...

Page 2: ...ximum life and value from it Our warranty depends on you using the Tastic according to this user guide It will only take you a few minutes so please read on Contents Eco Tastic Range Pg 3 Safety Pg 4...

Page 3: ...257m3 hr or 72l s 12343 Eco Sensation 4 x 275 W Heat Vent Light 15 W CFL Centre Globe Half Heat Function Cutout 330 mm x 330 mm 200 mm Fan 348m3 hr or 97l s 12341 Eco Silhouette 4 x 375 W Heat Vent Li...

Page 4: ...stic lamp surround in position This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they...

Page 5: ...e Triumph 11341 2 7 m for the Sensation 12343 and 3 3 m for the Silhouette 12341 The Tastic half heat function is available on the 4 lamp models and is another energy saver allowing you to adjust the...

Page 6: ...cavity itself should be well ventilated to outside so that moist air can be removed Local building codes may require flueing to outside through roof or as per Fig 5 page 8 for flat roof installation W...

Page 7: ...batts Figure 3 measurement A Model No 11341 75 mm min where there is good ventilation to the sides of the unit 100 mm min where ventilation to the sides of the unit is restricted Model No s 12341 123...

Page 8: ...the same fan switch as the Tastic see circuit diagrams NOTE S W A FAN LOW connection is the permanent active supply to the unit It must be provided so the unit can function as it was designed to do s...

Page 9: ...er AS NZS 3000 not supplied 12341 6 5A 50Hz 12343 4 8A 50Hz ACTIVE EARTH NEUTRAL C C C C 2 2 2 2 1 1 1 1 Terminal Block 7 way Thermal Fuse Thermal Switch 330 Ohm 20 W Ceramic Resistor Terminal Block 2...

Page 10: ...available for the Tastic it may be necessary to provide extra strengthening Eco Triumph approx 2 kg Eco Sensation Eco Silhouette approx 3 5 kg IMPORTANT Joists beams and rafters shall not be cut or no...

Page 11: ...lectric cables do not rest over the Tastic 5 To secure the Tastic in position push lower ends of springs apart Fig 10 Ceiling board thickness should be adjusted to enable springs to be fitted without...

Page 12: ...ation 275 watts max IXL Cat no 11300 NOTE Replace only with genuine IXL approved Hard Glass Infra Red lamps Light Bulb 15 W CFL IXL Cat no 12280 Light bulb is not covered by manufacturer s warranty Cl...

Page 13: ...th 375 watt lamps A You can only use heat lamps which have been fitted and approved for use in your product The rating label will state the maximum wattage for your product Q What is the maximum recom...

Page 14: ...itional ventilation We recommend that you visit our website for further details and suggestions on effectively ventilating your bathroom Q Can the installer rotate the IXL wall switch mechanisms A Yes...

Page 15: ...Fan Tastic 2 in 1 Heat and Light Ducted Tastics Ventilation Fans Ventilation and Light Units Eco Tastics Remote controlled Tastics Smart Switch Easy Duct Thermal Transfer System Tastic Neo IXL Range A...

Page 16: ...n equivalent current model where the balance of the warranty period from the original date of purchase will take effect 4 To the fullest extent permitted by law and subject always to Point 1 Sampford...

Page 17: ...enabling a Sampford IXL assessment b submit proof of purchase with your claim eg tax invoice or purchase receipt c where a property has been constructed by a builder developer and it is fitted with I...