background image

DR-VE-10-MO User Manual 

Ref.  Ed. 0 

 03/05/2021 

 

 

Introduction

 

 

The DR-VE-10-MO is a non-inverting single-ended modulators driver module for analog, pulse, 
or digital application. 
 

 

As  it  is  an  active  device,  the  DR-VE-10-MO  requires  a  DC  power  supply  [12V 

  0.45A].  The 

connection  between  the  power  supply  and  the  driver  is  performed  thanks  to  the  provided 
power supply cable (banana plugs to 2-pin Molex). 

 

 

For external control, the driver requires a connection to a computer via the provided COM cable 
(USB  to  3-pin  Molex)  and  the  use  of  a  provided  dedicated  software.  This  software  can  be 
downloaded from our website

https://photonics.ixblue.com/product/fbg/dr-ve-10-mo

 

 

 

 

Required equipments: 

o

 

DR-VE-10-MO  driver  with  iXblue  dedicated  heat-sink  or  adequate  cooling 
element. 

o

 

DC power supply [12V 

 0.45A] and provided power supply cable. 

o

 

Computer  with 

iXblue’s  “DR

-VE-10-MO  Control

”  software  or 

a  third-party 

HyperTerminal software and provided COM cable. 

o

 

Minimum Computer Requirements: 

 

Windows 7 / 8 / 10 

 

One USB port for each DR-VE-10-MO to drive. 

Summary of Contents for DR-VE-10-MO

Page 1: ...DR VE 10 MO...

Page 2: ...DR VE 10 MO User Manual Ref Ed 0 03 05 2021 2 Table of Contents TABLE OF CONTENTS 2 1 INTRODUCTION 3 2 SET UP 4 3 INTERFACE OPERATION 5 4 ADJUSTMENT PROCEDURE FOR SIGNAL OPTIMIZATION 8...

Page 3: ...l the driver requires a connection to a computer via the provided COM cable USB to 3 pin Molex and the use of a provided dedicated software This software can be downloaded from our website https photo...

Page 4: ...source for example Pulse Pattern Generator PPG is off 2 Attach a 50 Ohm load to output before supplying DC power to the amplifier 3 Set 12V on the DC power supply 0 45A max output OFF any standard DC...

Page 5: ...owing the instructions given by the install program This requires administrator privileges Launch the DR VE 10 MO Control application that was just installed by default a shortcut is added on the Wind...

Page 6: ...2021 6 After selecting your port click on Connect to activate the interface The DR VE 10 MO has to be powered up If the connection fails please check the cable connection or try another COM Port Inte...

Page 7: ...from 0 minimum value to 100 maximum value 3 allows the user to set its own Custom Mode parameters and to store them into the device memory by clicking on the button These settings can be recalled by...

Page 8: ...using the Amplitude parameter If the output level is too low adjust the Gain parameter or increase the incoming signal level Vin Do not increase too much the Gain parameter or input amplitude to avoid...

Page 9: ...g duration pulse Vin 130 mVpp 250 ns Vout 3 8 Vpp Gain 30 Amplitude 35 Crosspoint 40 Positive linear pulse Vin 120 mVpp ramp Vout 4 7 Vpp Gain 30 Amplitude 60 Crosspoint 80 Digital signal Vin 220 mVpp...