EN
Cleaning
1. Switch the machine an by means of the switch located an the back of the machine
2. Turn the 3 position switch on the front of the machine to position number
1
: 10,5 volts will be
displayed an the display also located an the front of the machine.
3. The brush is connected using the accompanying black cable to the black connector of the
machine.
4. Select the cleaning solution required for the weld area to be cleaned (Electrolyte A / B, C, C
Plus or LF),shake the solution vigorously and pour the required amount into the wide mouth
container.
5. Attach the earth clip to the part to be cleaned
6. Dip the brush complete with carbon brush into the wide mouth container shake off the excess
7. Gently stroke the brush over the weld area, the electrolytic process will clean the weld.
8. After cleaning is complete, wipe the cleaned area with a damp cloth and then dry with a
paper towel or cloth. Remove the electrolyte of the entire metal surface and neutralize the
surface with a cloth soaked in Neutralizer.
!
During prolonged use the brush may become hot,simply disconnect it from the cable
and cool in a bucket of water or under a tap,dry the brush, replace the brush tip and
reconnect to the black cable,or use another brush.
!
CAUTION
To avoid short circuit in the machine,change the brush end before all the brush fibers
are depleted. Whilst using chemicals an acid resistant apron,gloves and suitable eye
protection should be worn. Avoid getting solutions on your skin, if you do get the solu
-
tions on your skin,rinse off with plenty of clean water. Low alloy steels, residual cooling
liquid,drilling oil and similar substances can result In chemical reactions.
Polishing
1. Switch the machine on by means of the switch located on the back of the machine
2. Turn the 3 position switch on the front of the machine to position number
2
: 14 volts will be
displayed on the meter also located on the front of the machine.
3. The brush is connected using the accompanying black cable to the black connector of the
machine.
4. The red-marked ground wire must be connected to the work piece via the ground clamp.
5. Decant a little of the corresponding electrolyte (Electrolyte C or Electrolyte C Plus for polishing)
into the wide neck receptacle provided and immerse the brush.
6. Brush over the area to be polished several times until the desired finish is achieved.
!
During prolonged use the brush may become hot, simply disconnect it from the cable,
remove the brush and cool in a bucket of water or under a tap, dry the brush, replace
the brush tip and reconnect to the black cable, or use another brush
!
CAUTION
To avoid short circuit in the machine, change the brush end before all the brush fibers
are depleted. Whilst using chemicals an acid resistant apron, gloves and suitable eye
protection should be worn. Avoid getting solutions on your skin, if you do get the solu
-
tions on your skin, rinse oil with plenty of clean water.
Please refer to the material safety data sheets of the individual electrolytes. Low alloyed steels,
residual coolant, drilling oil and similar substances may cause chemical reactions.
16