2-1. Power Connection
1. Each machine has its own primary power cable, it must be connected to the mains
through a grounded power outlet on the right!
2. Power cable must be plugged into an appropriate power outlet!
3. Multimeter to check that there is power band in right.
2-2 . Accession output lines
1 Each machine has two swivel connectors, you can connect the panel tightly. Check
that well join cables , or damaged on both sides , can burn !
2 Electrode cable to the negative pole , while the workpiece (body) to the positive
pole connected .
3 Care should be taken of the electrode wire. Generally, there are two ways of switch
-
ing the rectifier welding machine: positive and negative connections . Positives:
electrode “-”, while the work on the “+ “ to . Negatives: piece work “ - “ electrode
while “+” is linked to . The proper practice mode , choose as faulty switching unsta
-
ble arc and cause a lot of splashing . In this case, switch the polarity to avoid incor
-
rect use of the machine !
4 If the work is too far away from the machine ( 50 - 100m) and secondary wire is too
long, you have to increase the wire cross -section to avoid voltage drop.
Installation diagram (MIG)
Installation diagram (TIG)
Installation diagram (STICK)
EN-6
Summary of Contents for 8PMIG205DIG
Page 12: ......
Page 24: ......
Page 26: ...CUPRINS ÚVOD 3 POZOR 4 HLAVNÉ PARAMETRE 5 INŠTALÁCIA 6 PREVÁDZKA 7 OPATRENIA ÚDRŽBA 10 SK 2 ...
Page 36: ......
Page 37: ...CUTTING EDGE WELDING R MANUALE D UTILIZZO POCKETMIG 205 DSC DIGITAL SYNERGIC ...
Page 48: ......
Page 60: ......
Page 72: ......
Page 75: ......
Page 77: ......
Page 79: ......
Page 80: ...www iweld hu ...