HU
EN
16.7
V
03.5
2-4.
Checking
1. Whether the machine is connected to standard to earth.
2. Whether all the connections are well-connected. (esp. that between the earth clamp and the
work piece)
3. Whether the output of the electrode holder and earth cable is short-circuited.
4. Whether the pole of the output is correct.
5. The welding splash may cause
fi
re, so make sure there is no
fl
ammable materials nearby.
2-3
Connect the wire feeder
1. The long axis of the wire feeder lock the wire roller that speci
fi
c wire. Make sure that
the wire roller is suitable for the wire used!
2. Wire should roll down clock wise, then cut the line, off-stage, it is only after pinning it
on!
3. Tighten the hold-down screws on the wire, put the wire into the wire feed guide
wheel and thread the wire to the welding torch.
4. Press the button on the wire feeder to the welding torch into the wire.
3. Operation Instructions
3-1.
Control panel layout
No.
Description
1
MMA/MIG switch key
2
VRD/2T/4T switch key
3
Wire diameter selection key (Ø0.8/1.0/1.2mm)
4
Data selection key (MENU)
5
Multifunctional data adjusting knob
6
Store mode selection key (Memory 1/2/3)
7
Gas check
8
Wire check
9
Multifunctional data display
7
Summary of Contents for 800MIG320DS