Page 12 of 21
iWave Systems Confidential.
Telematics Control Unit Product User Manual
3.2
Setting up Telematics Solution for Flashing
Insert the jumpers as shown in the image (1) and image (2) of Figure 13
Power on the Telematics control unit. Follow the procedure as mentioned in Figure 8
Connect one end of the USB Cable to the USB port of the Telematics control unit.
Connect other end of the USB cable to the PC.
Figure 13: Hardware setup to flash the Telematics control unit
Make sure that the Telematics control unit is powered on before connecting the USB flashing cable.
Remove the USB flashing cable before powering off the device after flashing.
3.3
Binary Programming
Use USB type A to micro-B cable to connect the Telematics control unit with host PC via USB OTG port.
Extract the <MFG_Tool>.zip file from MFG_TOOL folder.
Navigate to “MFG_TOOL/<MFG_Tool>” folder and double click on “MfgTool2.exe” file.
The MFG Application will open and will display the current operation in status text box.
If the device is detected, then "HID-compliant vendor-defined device" message will be displayed in the
status box.
Figure 14: Platform detection
Click on the Start button, MFG Tool will start programming binaries into boot media.