TROUBLESHOOTING PROCEDURES
Symptom
•Skipping
•Spattering
•Trigger sticks (back and forth)
•Trigger sticks (up and down)
Problem
•Dried paint on needle tip (Tip-Dry)
•Pigment too thick
•Air pressure too high
•Improper nozzle to body connection
•Dirty airbrush
•Cracked or damaged nozzle
•Dried paint on needle tip (Tip-Dry)
•Pigment build-up in needle cap
•Air pressure too low
•Pigment too thick
•Dirty airbrush
•Dirty airbrush
•Dried out air valve packing o-ring
Solution
•Clean with cotton swab dipped in cleaner
•See paint preparation
•See specific compressor instructions to
lower the air pressure
•See nozzle (#3) to reseat the nozzle
•See cleaning the airbrush between colors
•See cleaning the needle
•See nozzle (#3) to replace the nozzle
•Clean with cotton swab dipped in cleaner
•Unscrew #1 and clean with cotton swab
•See specific compressor instructions
to raise the air pressure
•See paint preparation
•See cleaning the airbrush between colors
•See cleaning the needle
•See cleaning the airbrush between colors
•See cleaning the needle
•Lube trigger shaft