IWAKI APN-P60-W Instruction Manual Download Page 20

T847-1 '13/07

(   )Country codes

IWAKI CO.,LTD.

 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan

TEL:(81)3 3254 2935 FAX:3 3252 8892(http://www.iwakipumps.jp)

Australia IWAKI Pumps Australia Pty. Ltd.

TEL : (61)2 9899 2411 FAX : 2 9899 2421

Italy

IWAKI Europe GmbH, Italy Branch

TEL : (39)0444 371115 FAX : 0444 335350

Austria

IWAKI EUROPE GmbH

TEL : (49)2154 92540 FAX : 2154 9254 48

Korea

IWAKI Korea Co.,Ltd.

TEL : (82)2 2630 4800 FAX : 2 2630 4801

Belgium IWAKI Belgium n.v.

TEL : (32)1367 0200

FAX : 1367 2030

Malaysia IWAKIm Sdn. Bhd.

TEL : (60)3 7803 8807 FAX : 3 7803 4800

China

IWAKI Pumps (Shanghai) Co., Ltd.

TEL : (86)21 6272 7502 FAX : 21 6272 6929

Norway

IWAKI Norge AS

TEL : (47)23 38 49 00 FAX : 23 38 49 01

China

IWAKI Pumps (Guangdong) Co., Ltd.

TEL : (86)750 3866228 FAX : 750 3866278

Singapore IWAKI Singapore Pte. Ltd.

TEL : (65)6316 2028 FAX : 6316 3221

China

GFTZ IWAKI Engineering & Trading (Guangzhou)

TEL : (86)20 8435 0603 FAX : 20 8435 9181

Spain

IWAKI Europe GmbH, Spain Branch

TEL : (34)93 37 70 198 FAX : 93 47 40 991

China

GFTZ IWAKI Engineering & Trading (Beijing)

TEL : (86)10 6442 7713 FAX : 10 6442 7712

Sweden

IWAKI Sverige AB

TEL : (46)8 511 72900 FAX : 8 511 72922

Denmark IWAKI Nordic A/S

TEL : (45)48 24 2345 FAX : 48 24 2346

Switzerland IWAKI (Schweiz) AG

TEL : (41)26 674 9300 FAX : 26 674 9302

Finland

IWAKI Suomi Oy

TEL : (358)9 2745810 FAX : 9 2742715

Taiwan

IWAKI Pumps Taiwan Co., Ltd.

TEL : (886)2 8227 6900 FAX : 2 8227 6818

France

IWAKI France S.A.

TEL : (33)1 69 63 33 70 FAX : 1 64 49 92 73

Taiwan

IWAKI Pumps Taiwan (Hsin-chu) Co., Ltd.

TEL : (886)3 573 5797 FAX : (886)3 573 5798

Germany IWAKI EUROPE GmbH

TEL : (49)2154 9254 0 FAX : 2154 9254 48

Thailand IWAKI (Thailand) Co.,Ltd.

TEL : (66)2 322 2471 FAX : 2 322 2477

Holland IWAKI Europe GmbH, Netherlands Branch

TEL : (31)547 293 160 FAX : 547 292 332

U.K.

IWAKI Pumps (UK) LTD.

TEL : (44)1743 231363 FAX : 1743 366507

Hong Kong IWAKI Pumps Co., Ltd.

TEL : (852)2 607 1168 FAX : 2 607 1000

U.S.A.

IWAKI AMERICA Inc.

TEL : (1)508 429 1440 FAX : 508 429 1386

Indonesia IWAKI Singapore (Indonesia Branch)

TEL : (62)21 690 6606 FAX : 21 690 6612

Vietnam IWAKI pumps Vietnam Co.,Ltd.

TEL : (84)613 933456 FAX : 613 933399

Summary of Contents for APN-P60-W

Page 1: ...Read this manual before use of product IWAKI Gas Liquid Transfer Pump APN P60 W built in type Instruction Manual...

Page 2: ...to the pump For the Safe and Correct Handling of the Pump Safety Instruction section deals with important details about handling of the product Before use read this section carefully for the preventio...

Page 3: ...sistant gloves a mask and a face shield during disassembly assembly or maintenance work Electrical shock Prohibited Prohibited No remodeling Wear protectors WARNING Electrical shock WARNING Use specif...

Page 4: ...se of the pump in wet or extremely humid locations could lead to electric shock or short circuit CAUTION Prohibited Prohibited Caution Prohibited Prohibited Electrical shock Prohibited CAUTION Donotto...

Page 5: ...uid is transferred from the inlet to outlet 3 Before use check the specification limitation and hazardous nature of the pump 1 Unpacking Inspection On unpacking the product check the following points...

Page 6: ...A Tube ID 2400 1200 2 0 08 47 99 1000 500 2 0 05 24DC 0 86 5 5 240 NOTE1 Observe the maximum discharge pressure NOTE2 The max liquid flow is based on the operation with clean water at 20 C and may ch...

Page 7: ...Dimension in mm 5 Outline 31 12 3 2 5 5 11 95 6 300 52 55 19 13 51 3 13 8 M3 Effective depth is 6mm 42 32 52 5 IN OUT IN OUT APN P60GD4 W Dimension in mm 6 300 31 12 3 2 5 5 11 41 37 64 5 15 95 52 55...

Page 8: ...0 C 2800 Pressure MPa Air Flow ml min Vacuum kPa abs Pressure MPa Liquid transfer with clean water at 20 C Liquid Flow ml min Pump head Name plate Model and MFG No Production number are described Driv...

Page 9: ...racket 2 2 Valve 4 35 Bearing 2 3 Valve seat A 2 40 Motor 1 4 Diaphragm 2 60 Set screw M3 8 4 8 Eccentric cam 2 62 Screw washer M3 16 8 11 Bracket cover 2 63 Screw 2 6 4 13 Bearing 2 66 Screw M3 6 4 1...

Page 10: ...n 5 and 40 C Liquid tempera ture should be between 10 and 40 C 1 Before Installation Read through this instruction manual before use Carry out installation work with a full understanding Installation...

Page 11: ...It may pre vent the motor from starting causing burning out or may damage the diaphragm or piping Do not tube pump heads in series It may prevent the motor from starting causing burning out or may da...

Page 12: ...or easy access and mainte nance 2 Pump fixation Use M3 bolts to anchor the pump CAUTION Do not install the pump on a unsta ble place 2 2 Tubing 1 Before tubing The short tubing with the minimum bends...

Page 13: ...our nearest distributor for wiring as necessary Before wiring 1 Confirm that power is disconnected before work 2 Wiring work should be done in accordance with local elec tric codes Use the recommended...

Page 14: ...signal generator NOTE The black power and signal leads are leading from the common negative terminal of the pump 3 Pump speed signal polarity The green signal lead leading from the pump is positive po...

Page 15: ...not use solvents such as benzine alcohol thinner for maintenance or cleaning otherwise a coat discolours or comes off Always use a suction valve to adjust an air flow If the compressed air or liquid...

Page 16: ...ore full scale operation Always adjust an air flow by a suction valve 5 Points to be checked during operation After starting check a pressure gauge to see if suction and discharge line pressure are co...

Page 17: ...ump Voltage reduction Increase voltage to the rated level Higher suction pressure than atmospheric Reduce suction pressure Contact us for the measures marked with 2 Maintenance Inspection Handling of...

Page 18: ...n or 47 99KPa abs or below vacuum 4000hr 4000hr 4000hr gas transfer 0MPa 4000hr 4000hr 4000hr liquid transfer 0 05MPa or below pressurization 2000hr 2000hr 2000hr Part lives vary with the pressure tem...

Page 19: ...ves and gas kets with new ones 3 Push down the diaphragm until it bottoms out and then rebuild the pump head Fasten the fix ing screws by 0 58N m NOTE1 Finish either pump head first and then start wit...

Page 20: ...AKI Europe GmbH Spain Branch TEL 34 933770198 FAX 934740991 China GFTZIWAKIEngineering Trading Beijing TEL 86 1064427713 FAX 1064427712 Sweden IWAKI Sverige AB TEL 46 851172900 FAX 851172922 Denmark I...

Reviews: