7
—
⑤
Precautionary measures
1
Do not operate the pump dry.
The pump should not be operated
dry or while the suction side is
closed. This will wear out the gears
and bearings.
2
Range of liquid temperatures
The pump can be used with liquids
in the following temperature range.
The performance will change
depending on the temperature of the
liquid.
● Type S :
0 ~ 50ºC
● Type T :
0 ~ 95ºC
In case the liquid being handled is
a solvent, the gears may swell to
force the pump to stop, in the worst
case. For further information,
please contact us.
3
Liquid viscosity
Highly viscous liquid cannot be
transferred.
● Type S : up to 30
mPa·s
● Type T : 80
mPa·s(with a 100W
motor)
200mPa·s(with a 150W
motor)
Highly viscous
liquid