11
Ov
e
rv
ie
w
,QWURGXFWLRQ
Pump characteristics, features and part names are described
in this section.
,QWURGXFWLRQ
Pump structure & Operating principle
The HRP series is a diaphragm metering pump which consists of a pump
head, drive unit and control unit. A diaphragm is directly driven by electromag-
netic force.
3ULQFLSOHRIRSHUDWLRQ
7KHSXOVHVLJQDOFRQWUROVWKHHOHFWURPDJQHWLFIRUFHDQGVSULQJIRUFHLQRUGHU
WRPDNHUHFLSURFDWLQJPRWLRQ7KHUHFLSURFDWLQJPRWLRQLVWUDQVIHUUHGWRD
GLDSKUDJPWKURXJKDSOXQJHUDQGWKHQYROXPHWULFFKDQJHRFFXUVLQWKHSXPS
KHDG7KLVDFWLRQWUDQVIHUVOLTXLGDORQJZLWKSXPSKHDGYDOYHDFWLRQ
3XPSKHDG
'ULYHXQLW
6SULQJ
3XPSKHDGYDOYH
'LVFKDUJHVLGH
3XPSKHDGYDOYH
6XFWLRQVLGH
3OXQJHU
'LDSKUDJP
&RQWUROXQLW
Overview
IN