- 10 -
2. Installation/ Tubing/ Electrical wiring
2.1 Installation
1. Do not expose the pump to
direct sunlight, vibration and
wind & rain.
2. Keep good ventilation. The
pump should always be free
from the possibility of getting
wet.
3. Ambient temperature should
not fall below 0°C or exceed
40°C. Observe the allowable
maximum ambient humidity
of 90%RH.
4. Install the pump in a clear
and level place.
Select a convenient place
for maintenance and inspec-
tion.
5. Pump fixation
Set the pump baseplate on a
concrete foundation and fasten
anchor bolts tightly to prevent
the pump from vibrating during
operation.
CAUTION
Do not install the pump on a
unstable place.
2.2 Tubing
1. The short tubing with the mini-
mum bends is optimal to reduce
resistance.
2. Use vinyl tubes resistant to the
pumping pressure.
CAUTION
Do not have tubing bent or
pressed. Otherwise, the tube
end may break.
Installation
If you notice any abnormal or dangerous conditions, suspend
operation immediately and inspect/solve problems.
WARNING