Maintenance

Check the pressure gauge

(Twice a year)
The pressure gauge in the lower section of the electric boiler must be 
checked twice a year. This is particularly important during autumn when 
the heating season starts. The pressure gauge should be at 0.5 – 1.5 bar. If 
the pressure is lower than 0.5 bar, fi ll with water up to around 1.0 bar. The 
knob for topping up the heating water is located in the connection area.

Clean the discharge water vessel

(Twice a year)
Wash the discharge water vessel with warm water and anti-bacterial 
cleaning agent to remove dirt and algae. Rinse and check that the water 
runs off through the hose.

Check the safety valves

(Twice a year)
Check the safety valves for tap water and heating water by opening and 
closing them using the valve knobs.

Water may drip from the escape pipe, this is normal. The pipe opening must 
never be sealed.

If the hot water heater must be drained, call a service engineer.

Maintenance

Filling 

heating 

water

Pressure 

gauge

Discharge water vessel

Safety valve tap water

Summary of Contents for 290 A/W

Page 1: ...IVT 290 A W Electric boiler User Guide Art no 12322 Version 1 0...

Page 2: ...t at a low level while you are away on holiday IVT is the leading heat pump manufacturer in the Nordic Countries More than every second heat pump comes from IVT We have worked with solutions to reduce...

Page 3: ...er works 6 Component parts 7 Maintenance 8 Check the pressure gauge 8 Clean the discharge water vessel 8 Check the safety valves 8 What to do if a fault occurs 9 Protective anode 9 Overheat protection...

Page 4: ...panel This guide contains a description of 290 A W what it consists of main tenance etc The control unit and settings for Optima with 290 A W are described in the Optima guide It is important as the...

Page 5: ...contains a control panel with graphic presentation Most settings needed to give the installation the best possible function in your house are made via the control panel by the installer or are preset...

Page 6: ...ter shell and heats up the hot water until the hot water requirement is met While it is doing so no heat is produced The switch between heating and hot water production occurs automati cally at a cert...

Page 7: ...eat to the radiator system The temperature of the radiator system is regulated via the flow line sensor T1 and the heating settings in the control unit Extra hot water and hot water peaks The electric...

Page 8: ...tima are made here In addition there are 3 way valves mixing valves etc Hot water heater The water heater is double shelled and stainless steel It holds 160 litres of water Control panel with graphic...

Page 9: ...n area Clean the discharge water vessel Twice a year Wash the discharge water vessel with warm water and anti bacterial cleaning agent to remove dirt and algae Rinse and check that the water runs off...

Page 10: ...eat protection is on the front of the electric box This is a protection device that should normally not trip If however it does trip reset it by pressing in the button firmly If the overheat protectio...

Page 11: ...5 60 1 170 65 0 980 70 0 824 75 0 696 80 0 590 85 0 503 90 0 430 IVT 290 A W Output electric element kW 9 13 5 Output circulation pump kW 0 2 Electrical supply 400V 3N 50Hz Max power consumption kW 9...

Page 12: ...IVT Industrier AB Sweden www ivt se mailbox ivt se...

Reviews: