background image

4

Important information

Electric boiler IVT 290 A/W belongs to the latest family of heating 
products from IVT Industries. In heat pump systems with Optima 600, 900 
and 1100, 290 A/W is used as electrical additional heat and for production 
of hot water.

The electric boiler is available in two versions, 9 kW or 13.5 kW. 

The heat pump system is controlled by a Rego 800 control unit, which is 
in 290 A/W. The control unit controls and monitors the total system using 
different settings for heating, hot water, other operations and maintenance. 
The settings are made by the installer and the user via a control panel.

This guide contains a description of 290 A/W, what it consists of, main-
tenance, etc. The control unit and settings for Optima with 290 A/W are 
described in the Optima guide. It is important, as the user, that you read 
through the Optima guide.

Important information for the user

Note

For a comprehensive understanding 
please read the Guide for Optima 600-
1700. There the Rego 800 monitoring 
and control system is fully described.

For the user

Only a trained and quali

Þ

 ed technician may carry out repairs to this machine. Incorrect repairs 

can lead to serious risks to the user, and a reduction in savings. 
Visits from an authorised Service representative to make corrections or adjustments after such 
a repair, cannot in such cases be carried out free of charge, not even during the warranty period.

Note

Summary of Contents for 290 A/W

Page 1: ...IVT 290 A W Electric boiler User Guide Art no 12322 Version 1 0...

Page 2: ...t at a low level while you are away on holiday IVT is the leading heat pump manufacturer in the Nordic Countries More than every second heat pump comes from IVT We have worked with solutions to reduce...

Page 3: ...er works 6 Component parts 7 Maintenance 8 Check the pressure gauge 8 Clean the discharge water vessel 8 Check the safety valves 8 What to do if a fault occurs 9 Protective anode 9 Overheat protection...

Page 4: ...panel This guide contains a description of 290 A W what it consists of main tenance etc The control unit and settings for Optima with 290 A W are described in the Optima guide It is important as the...

Page 5: ...contains a control panel with graphic presentation Most settings needed to give the installation the best possible function in your house are made via the control panel by the installer or are preset...

Page 6: ...ter shell and heats up the hot water until the hot water requirement is met While it is doing so no heat is produced The switch between heating and hot water production occurs automati cally at a cert...

Page 7: ...eat to the radiator system The temperature of the radiator system is regulated via the flow line sensor T1 and the heating settings in the control unit Extra hot water and hot water peaks The electric...

Page 8: ...tima are made here In addition there are 3 way valves mixing valves etc Hot water heater The water heater is double shelled and stainless steel It holds 160 litres of water Control panel with graphic...

Page 9: ...n area Clean the discharge water vessel Twice a year Wash the discharge water vessel with warm water and anti bacterial cleaning agent to remove dirt and algae Rinse and check that the water runs off...

Page 10: ...eat protection is on the front of the electric box This is a protection device that should normally not trip If however it does trip reset it by pressing in the button firmly If the overheat protectio...

Page 11: ...5 60 1 170 65 0 980 70 0 824 75 0 696 80 0 590 85 0 503 90 0 430 IVT 290 A W Output electric element kW 9 13 5 Output circulation pump kW 0 2 Electrical supply 400V 3N 50Hz Max power consumption kW 9...

Page 12: ...IVT Industrier AB Sweden www ivt se mailbox ivt se...