![Ivoclar Vivadent Programat EP 5010 Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/ivoclar-vivadent/programat-ep-5010/programat-ep-5010_operating-instructions-manual_2097656023.webp)
23
5.1 Introduction to the operation
5.1.1 Control unit
The Programat EP 5010 is equipped with a wide-screen colour display. The furnace can be intuitively operated by means of
the membrane-sealed keypad and the touch screen. The touch buttons can be actuated by slightly tapping the display with
the fingertip and the furnace runs the desired function.
The user interface in the display is divided into three sections:
1.
Information bar
(e.g. indication of the current furnace temperature, selected program type, etc.)
2.
Main screen
(e.g. editing firing programs, changing the settings, etc.)
3.
Navigation bar
(e.g. scrolling, scrolling to higher levels, opening favourite programs, etc.)
5.1.2 Explanation of the key functions
Key
Function
HOME key
Switch to home screen (main menu).
PROGRAM key
Press once: Display of the currently selected program.
Press twice: Switch to the program selection via number entry.
CHANGE OPERATING MODE key
By pressing this key, you can switch between the firing and the press mode.
IRT key
With this key, the infrared image of the object can be displayed during the closing
process.
POWER SAVING key
By pressing this key, the power-saving function is activated (only possible with the furnace
head closed and the furnace on idle). The display shows the power-saving icon. Pressing
any key ends the automatically activated power-saving function.
OPEN FURNACE HEAD key
Quick cooling with the furnace head open:
If the furnace head is completely open and the OPEN FURNACE HEAD key is pressed
again, the quick cooling function is activated, e.g. the vacuum pump is switched on for
5 minutes. This function can be stopped at any time by pressing the STOP, CLOSE
FURNACE HEAD or START key. This function can be activated any time when the furnace
head is open.
CLOSE FURNACE HEAD key
5. Operation and Configuration
PRESSING
HOLDING
READY
NOT READY
PREDRYING HEATING
COOLING
Index
Änderung
Datum
Name
Gepr.
Gez.
Datum
Name
Maßstab
Maße ohne
Werkstoff:
Toleranzangabe:
= Fanger %%c= 6 H7
= Lochpfeife %%c= 2.8
L
Format
Zeichn.-Nr.:
Bezeichnung:
Projekt-Nr.:
Es gilt Urheberschutz nach DIN 34
Oberfläche:
Werkzeug-Nr.:
d110.2588_Modi_99_-
Druckzeichnung
-
A3
20.07.2016
SJ
20.07.2016
SJ
Blatt 1 von 1
1059.0010.99
Siehe Stückliste
-
bis 300 %%P0,2
über 300 %%P0,3
1:1
P
SAVING
POWER
START
P
O
T
S
5010
EP
Programat
13.99 FFR = RAL 5012 Lichtblau
0505.5012.000.00
12.99 FFR = RAL 4010 Telemagenta
0505.4010.000.00
15.99 FFR = RAL 9016 Verkehrsweiß Verschwindeef. 0505.9003.444.72
14.99 FFR = RAL 7035 Lichtgrau (Hinterdruck)
0505.7035.000.00
11.99 FFR = RAL 5002 Ultramarinblau
0505.5002.000.00
10.99 FFR = RAL 3020 Verkehrsrot
0505.3020.000.00
9.99 FFR = RAL 6024 Verkehrsgrün
0505.6024.000.00
8.99 FFR = RAL 2003 Pastellorange
0505.2003.000.00
7.99 FFR = RAL 1018 Zinkgelb
0505.1018.000.00
6.99 FFR = RAL 9016 Verkehrsweiß
5.99 FFR = RAL 7035 Lichtgrau
4.99 FFR = RAL 3020 Verkehrsrot
3.99 FFR = RAL 6024 Verkehrsgrün
2.99 FFR = RAL 5002 Ultramarinblau
1.99 FFR = RAL 7012 Basaltgrau
0505.9003.000.00
0505.7035.000.00
0505.3020.000.00
0505.6024.000.00
0505.5002.000.00
0505.7012.000.00
Farben Frontfolie :
= Ausstanzung
#=Index siehe Grundprojekt
Kunden-Artikel Nr. : EP5010
Farben der Zeichnung entsprechen nicht den Siebdruckfarben
Abmessungen siehe Fertigungszeichnung
Hinweise :
3 SM-LPV"#" = Isolack
2 SM-LPV"#" = Graphit
1 SM-LPV"#" = SLF
4 SM-LPV"#" = SLF
Farben SMD-Leiterplatte :