Control Inputs

Each control port can support either RS485 smart controls, or 1 analog switch, 1 analog potentiometer, and 1 

logic output.  The number of analog controls, and logic outputs can be dramatically increased by the use of an 

RMPC I/O expander.  RMPC expanders allow a 4, 8, or 12 fold expansion of the number of analog controls, 

and logic outputs, and combine them into a smart control with a single CAT5E or better cable back to the MAP 

device control port.

Switches

Switches inputs are internally ‘pulled up’ to +5VDC via 1kOhm resistor.  No external voltage source is neces-

sary to create contact closure to ground.  Switches are wired from pin 1 to pin 7 or pin 8 of the RJ45 connector.

1

2

3

4

5

6

7

8

RJ45 JACK

TIA/EIA 568B STANDARD

Switch

Potentiometers

Potentiometers are wired with ref10V on pin 3, a wiper on pin 2, and a ground on pin 7, or pin 8.  High 

performance pots with track resistance between 10kOhms and 100kOhms are recommended.

1

2

3

4

5

6

7

8

RJ45 JACK

TIA/EIA 568B STANDARD

Ref

er

enc

e = 10V

W

iper

Gr

ound

Summary of Contents for iFlex 620

Page 1: ...MAP Series Audio Mixer Installation Guide Model iFlex 620 Firmware Rev 2 065 IP Address 192 168 0 150 Subnet Mask 256 256 256 0 Serial Number 2051A306D2 Date 5 12 2014 Time 11 27 14...

Page 2: ...shows information on the mixer model number firmware revision current IP address and subnet mask serial number date and time Model iFlex 620 Firmware Rev 2 065 IP Address 192 168 0 150 Subnet Mask 256...

Page 3: ...itor control a unit layout in real time using the SonataTM software This port is also used for sending ethernet commands UDP or TCP in Decimal Hexa decimal ASCII Binary BYTES etc to control 3rd party...

Page 4: ...ols such as potentiometers contact closures and LED outputs Any Ivie SmartCon trol that is plugged into this port will self identify in the hardware programming screen for assignment to layout element...

Page 5: ...better cable back to the MAP device control port Switches Switches inputs are internally pulled up to 5VDC via 1kOhm resistor No external voltage source is neces sary to create contact closure to gro...

Page 6: ...30V DC For logic outputs that will drive LED s directly without any other source see the RMPC line of I O expander modules See also the Relay module of the MAP series module list for power relay opti...

Page 7: ...ice M1 M4 1 2 3 4 QUAD IN 3 Wire 2 Wire 1 2 3 4 QUAD OUT 3 Wire 2 Wire INPUTS SHIELD OUTPUTS SHIELD Technical Specifications Frequency response 20 Hz 20 KHz THD N 20 Hz 20KHz Equivalent Input Noise 20...