IVIE iFlex 620 Installation Manual Download Page 4

3

between source and destination channels.  Ethernet audio channels only go to those destination channels that 

request them, and the coordination of these sources and destinations is handled by the IGMP switch/router.

USB

Like the ethernet connection, the USB connection can be used to program, monitor, and control the MAP-6L 

(no USB connection available on a MAP-3 unit).  This connection can be used to send and receive files from the 

MAP unit, as well as configure the unit, and control any system layout.  Unlike the ethernet connection, there 

are no audio channels available via USB.

Logic I/O

The Logic I/O ports on the rear panel of a MAP unit are RS-485 communication ports for Ivie SmartControls

©

as well as physical controls, such as potentiometers, contact closures, and LED outputs.  Any Ivie SmartCon-

trol

©

 that is plugged into this port will self-identify in the hardware programming screen for assignment to 

layout elements.  Ivie SmartControls

©

 use standard CAT-5E or better cables.

Note - Ivie SmartControls

©

 r24VDC power, which is supplied on pins 4 and 5 of the 

RJ45 connector.  For consistency in iFlex installations, and assistance in technical support, Ivie 

uses the TIA/EIA 568B standard for RJ45 connector wiring.  Care should be taken in the wiring 

of RJ45 connectors on the CAT-5e cable, as cross-wiring of the +24VDC can cause damage to 

the RS485 communications electronics inside the MAP unit.

1

2

3

4

5

6

7

8

RJ45 JACK

TIA/EIA 568B STANDARD

The pinout for the Logic I/O ports is shown below.

Pin

Assignment

1

Switch in (RS-485 Data A)

2

Pot wiper (RS-485 Data B)

3

(10 VDC)

4

+24 VDC

5

+24 VDC

6

LED out (RS-485 Reset)

7

Ground

8

Ground

Summary of Contents for iFlex 620

Page 1: ...MAP Series Audio Mixer Installation Guide Model iFlex 620 Firmware Rev 2 065 IP Address 192 168 0 150 Subnet Mask 256 256 256 0 Serial Number 2051A306D2 Date 5 12 2014 Time 11 27 14...

Page 2: ...shows information on the mixer model number firmware revision current IP address and subnet mask serial number date and time Model iFlex 620 Firmware Rev 2 065 IP Address 192 168 0 150 Subnet Mask 256...

Page 3: ...itor control a unit layout in real time using the SonataTM software This port is also used for sending ethernet commands UDP or TCP in Decimal Hexa decimal ASCII Binary BYTES etc to control 3rd party...

Page 4: ...ols such as potentiometers contact closures and LED outputs Any Ivie SmartCon trol that is plugged into this port will self identify in the hardware programming screen for assignment to layout element...

Page 5: ...better cable back to the MAP device control port Switches Switches inputs are internally pulled up to 5VDC via 1kOhm resistor No external voltage source is neces sary to create contact closure to gro...

Page 6: ...30V DC For logic outputs that will drive LED s directly without any other source see the RMPC line of I O expander modules See also the Relay module of the MAP series module list for power relay opti...

Page 7: ...ice M1 M4 1 2 3 4 QUAD IN 3 Wire 2 Wire 1 2 3 4 QUAD OUT 3 Wire 2 Wire INPUTS SHIELD OUTPUTS SHIELD Technical Specifications Frequency response 20 Hz 20 KHz THD N 20 Hz 20KHz Equivalent Input Noise 20...