SkidWeigh
Plus
ED3/4-IM: Quick Reference Calibration &
Operation Guide
SkidWeigh Plus Operation Guide (continued)
Step 4
.:
Do not manipulate the tilt, side shift or fourth lever function during the weighing process
Note
: It is important to maintain consistency in the above process, similar to the process in the
calibration guide. All SkidWeigh systems are supplied with a mast sticker that details the above. If
you require a lost or replacement sticker please contact or go to www.skidweigh.com.
2.) Accumulative Totalling
Note
: Accumulative totalling allows you enter a multiple load weight measuring cycle and capture
the total weight.
Step 1.:
Lift the load in accordance to the above operation guide and wait till the first load is
displayed on the LCD screen.
Press (Enter Key
↵
)
to start accumulating loads.
Step 2.:
Repeat the lifting process,
Pressing the (Enter Key
↵
)
each time to move to the next
load. The system will automatically display the individual weight of the last load lifted as well as the
amalgamated total of all loads lifted in the multiple load measuring cycle.
Step 3.:
When the total number of loads required to be weighed has been reached.
Press (P)
to
complete the cycle. The information pertaining to the multiple load weigh cycle will be transferred to
a data source such as USB, print ticket, and or Base Station. The system will automatically be
reset.
3.) Waybill# Load Identification
Note
: Systems with the waybill option will allow you to code your load or series of loads with an
identification number.
Step 1.:
Lift the load in accordance to the above operation guide and wait till the first load is
displayed on the LCD screen.
Press (Enter Key
↵
)
to start accumulating loads. or
Press (P)
to
enter waybill#
Note
: Upon system prompt - enter first digit of waybill # and press
(Enter Key
↵
)
with each digit
added and to forward to the next digit press
(Enter Key
↵
)
When the last waybill digit is required
press
(Enter Key
↵
)
to complete load weight cycle ID#.
(A) By pressing
(Enter Key
↵
)
the accumulative load weight cycle with waybill# will be reset. Load
weight information will automatically be saved to USB, printer, and or Base Station, depending
on system.