IVDT SkidWeigh Plus ED3-IM Quick Reference Calibration & Operation Manual Download Page 6

  

SkidWeigh 

Plus

 ED3/4-IM: Quick Reference Calibration & 

Operation Guide

SkidWeigh Plus Operation Guide (continued)

Step 4

.: 

Do not manipulate the tilt, side shift or fourth lever function during the weighing process

 

Note

: It is important to maintain consistency in the above process, similar to the process in the 

calibration guide.  All SkidWeigh systems are supplied with a mast sticker that details the above.  If 
you require a lost or replacement sticker please contact or go to www.skidweigh.com.

2.) Accumulative Totalling 

Note

: Accumulative totalling allows you enter a multiple load weight measuring cycle and capture 

the total weight.

Step 1.: 

Lift the load in accordance to the above operation guide and wait till the first load is 

displayed on the LCD screen.  

Press (Enter Key

 

to start accumulating loads.

Step 2.: 

Repeat the lifting process,

 

Pressing the (Enter Key

 

each time to move to the next 

load.  The system will automatically display the individual weight of the last load lifted as well as the 
amalgamated total of all loads lifted in the multiple load measuring cycle.

Step 3.: 

When the total number of loads required to be weighed has been reached.  

Press (P) 

to 

complete the cycle.  The information pertaining to the multiple load weigh cycle will be transferred to 
a data source such as USB, print ticket, and or Base Station.  The system will automatically be 
reset.

3.) Waybill# Load Identification

Note

: Systems with the waybill option will allow you to code your load or series of loads with an 

identification number.

Step 1.: 

Lift the load in accordance to the above operation guide and wait till the first load is 

displayed on the LCD screen.  

Press (Enter Key

 

to start accumulating loads. or

 

Press (P) 

to 

enter waybill#

Note

: Upon system prompt - enter first digit of waybill # and press 

(Enter Key 

with each digit 

added and to forward to the next digit press 

(Enter Key 

)  

When the last waybill digit is required 

press 

(Enter Key 

)

 to complete load weight cycle ID#.

(A) By pressing 

(Enter Key 

)

 the accumulative load weight cycle with waybill# will be reset.  Load 

weight information will automatically be saved to USB, printer, and or Base Station, depending 
on system.

Summary of Contents for SkidWeigh Plus ED3-IM

Page 1: ... following code 742F Step 2 The system will automatically begin on slot 1 which from the factory will be programmed with 111 Enter the new 3 digit operator code and press enter Once accepted it will then move to slot 2 Repeat step 2 until all operator codes are entered into the system Step 3 Removing Operator Codes Power on the unit Enter 742F using the keypad Press enter until you come to the slo...

Page 2: ...t side shift or fourth lever function during the zeroing process Step 3 The system will ask you to Lower Empty Forks and then to Enter Known Weight Enter the load of the weight secured before the calibration process and press Enter Step 4 The system will now ask you to Lift Loaded Forks similar to Step 2 Do not manipulate the tilt side shift or fourth lever function during the zeroing process Step...

Page 3: ...Impact Buzzer Yes or No Select then press enter Step 5 If Yes was selected for Impact Buzzer the system will ask if you want it Continuous Yes or No Select then press enter Step 6 If No was selected for Continuous the system will ask you to enter a Time 1 60 Referring to seconds enter the value desired and press enter The system will let you know you are finished by displaying Impacts Configured 2...

Page 4: ...t operator check the system will ask an OSHA compliant safety check at start of shift This selection allows you to set your shift cycle The system will come preset with 8 hour shift continental 12 hour or daily 24 hour Step 1 With the lift truck powered on press F then 9 and enter the Supervisor Code Use the arrows to scroll to Set Safety Time and press enter Step 2 The system will prompt for Star...

Page 5: ...for the system to inform of completion and remove USB 2 Upload Data From USB to On board unit Step 1 With USB inserted into the back of the on board unit scroll to Upload Data and press enter Wait for the system to inform of completion and remove USB SkidWeigh Plus ED3 4 IM Weighing Operations Note Systems with the SkidWeigh Plus Weigh Scale will provide the ability to weigh pallets and or attachm...

Page 6: ...ad lifted as well as the amalgamated total of all loads lifted in the multiple load measuring cycle Step 3 When the total number of loads required to be weighed has been reached Press P to complete the cycle The information pertaining to the multiple load weigh cycle will be transferred to a data source such as USB print ticket and or Base Station The system will automatically be reset 3 Waybill L...

Page 7: ... part or unit weight to divide into the total of the load to a parts estimation count Enter the weight of the standardized part use the P key to input a decimal and press Enter Key to set system To reset system input 1 0 C Tare Allows the operator to weigh a load and subtract a known bin or container weight to arrive at a net load weight Tare default is automatically set to 0 To change input the k...