10
FUSE Replacement:
The fuse use on MT606 is:
BUSSMANN
Fast Acting, Glass Tube
Rating: 250VAC, 1A
Size: 5x20mm
Warning:
1. Make sure the power off before
replace the fuse.
2. Do not replace the fuse with a
different rating fuse.
2.2.2 Grounding Requirements
Chassis ground must be used. DC ground is not directly coupled to Earth ground
internally. It is preferable not to ground DC negative return to chassis ground as poor
site earths can introduce noise into a system, but if necessary an earth connection
should be made, from the power supply return point to the central star earth point.
Ground conductors should be as short and as large in size as possible. The conductors
must always be large enough to carry the maximum short circuit current of the path
being considered. Ground conductors should be connected to a tree from a central star
earth ground point. This ensures that no ground conductor carries current from any
other branch.
2.2.3 CE Requirements
To make an MT-600 comply with EMC directives, and to reduce susceptibility to
electrical interference, a separate #14 AWG ground wire should be taken to the chassis
ground terminal of the power connector. This ground connection should be run
directly to the central star earth connection point (as recommended in most
Installation Instructions).
2.2.4 Safety Guidelines
This section presents recommended installation practices, and procedures. Since no
two applications are identical, these recommendations should be considered as
guidelines.