background image

I.V.A.R. S.p.A.

Via IV Novembre, 181

25080 Prevalle (BS) – ITALY

T. +39 030 68028 – F. +39 030 6801329

[email protected] – www.ivar-group.com

I.V.A.R. S.p.A. si riserva il diritto di apportare miglioramenti e modifiche ai prodotti e alla relativa documentazione in qualunque momento e senza preavviso. Tutti i diritti sono 

riservati. La riproduzione completa o parziale è vietata senza il previo consenso del proprietario del copyright.

I.V.A.R. S.p.A. reserves the right to make enhancements and changes to products and relative documentation at any time without prior notice. All rights reserved. Reproduction, 

even partial, is forbidden without prior permission by the copyright owner.

Fig. 6

(a)

(d)

(b)

(e)

(c)

(f)

Fig. 6

(a)

(d)

(b)

(e)

(c)

(f)

8

300451-04-17

Summary of Contents for EQUICOMPACT

Page 1: ...300451 04 17 Manuale di istruzioni Instruction manual EQUICOMPACT ...

Page 2: ...solamenti singoli Ingombri in Fig 1 Descrizione I moduli di utenza sono gruppi polifunzionali che riuniscono in un solo punto i dispositivi di contabilizzazione diretta e valvole di controllo EQUICOMPACT è una soluzione versatile e dall ingombro ridotto per la gestione del calore La sua caratteristica valvola di zona a due vie lo rende adatto all utilizzo con pompe a portata variabile questo binom...

Page 3: ...iuse allentare i dadi agli estremi del tronchetto DIMA e rimuoverlo Posizionare le guarnizioni inserire il contatore volumetrico al posto del distanziale e serrare i dadi senza forzare f Piombare il contatore Messa in opera Fig 7 Secondo le modalità previste dal progettista effettuare il bilanciamento idraulico statico dell utenza procedendo come segue a Aprire le valvole di intercettazione del bl...

Page 4: ...sed shell does not require the addition of individual insulation shells Dimensions in Fig 1 Description User modules are multi functional groups combining metering devices and control valves in a single unit EQUICOMPACT is a flexible small footprint solution for heating management Its characteristics two way zone valve makes it suitable to the application with variable speed pumps this combination...

Page 5: ...lves of the domestic line are closed loosen the nuts at the endpoints of the template then remove it Position two new gaskets and the water meter instead of the template then tighten the nuts without forcing too much f Seal the meter Commissioning Fig 7 According to the designer specifications make the static balancing of the user plant by following these steps a Open the heating unit shut off val...

Page 6: ...03 98 230 80 115 70 130 G 1 G M10X1 M30X1 5 506576S EQCP25 230 80 70 130 G 1 G M10X1 M30X1 5 ART COD A B C D E F G H L M AC 860B 200199 510 510 444 444 450 450 130 80 110 36 AC 860L 200299 520 520 442 442 450 450 130 80 110 36 ART COD A B C D E F G H L M AC 860IB 506665B 530 530 400 400 470 470 130 80 92 43 Fig 1 7 6 4 3 2 8 5 1 9 Fig 3 Fig 2 C A B 6 300451 04 17 ...

Page 7: ...Fig 4 a b c Fig 5 a d g j b e h c f i 7 300451 04 17 ...

Page 8: ...que momento e senza preavviso Tutti i diritti sono riservati La riproduzione completa o parziale è vietata senza il previo consenso del proprietario del copyright I V A R S p A reserves the right to make enhancements and changes to products and relative documentation at any time without prior notice All rights reserved Reproduction even partial is forbidden without prior permission by the copyrigh...