9.4. Blower faults
Problem Cause Solution
Blower does not start.
No voltage supply.
Restore voltage supply.
Fuse is defective.
Check and, if necessary,
replace fuses.
Thermal
overload
protection switch is off.
(Check the full electrical
installation).
Reset thermal overload
protection switch.
Wiring is interrupted. Repair
wiring.
Motor stops or gets
overheated.
Motor is overloaded.
Remove the overload.
Voltage supply is
interrupted at 1 or several
phases.
Restore voltage supply.
Motor voltage is too low
due to the long supply line.
Shorten the supply line.
Table 4: Motor faults
10. Repair
The
"Typhoon"
does not have any parts that can be repaired by customers.
Send the air knife to Simco-Ion Netherlands for repair. Request an RMA form by sending an e-
mail to
. Pack the air knife properly and clearly state the reason for
return.