3
EASY 1-L
Issued 05/00
Figure 1
CONNECTION INSTRUCTIONS
The Manual Powder equipment is partially assembled in the factory.
Only certain cables and hoses must be connected by the customer
(see separate Assembly Instructions).
1.
Connect the hose for the compressed air supply from com-
pressed air circuit directly to the main air connection -
1.1 IN
on
the rear of the control unit (female thread: 1/4" B.S.P.).
The compressed air must be free from oil and water.
2. Connect the black hose for the fluidizing air to the corresponding
output (
1.5
) on the rear of the control unit and to the pressure
reducing valve (
9
)
on the back of the control unit.
3. Fit the grounding connection cable on the control unit with the
grounding screw, and the 5
m long grounding cable
with the clamping clip on
the booth or on the hanger
device.
4. Connect the gun cable with
the 7 pole plug on the rear
of the control unit on the
socket -
2.2
(Gun).
The PG 1 Manual powder gun
cannot be connected!
5. Connect the hose for
rinsing air
on the rinsing air
output -
1.4
and on the
powder gun.
6. Plug the injector in, and
connect the powder hose
on the injector and on the
powder gun.
7. Connect the red hose for
conveying air to the corre-
sponding output -
1.2
on
the rear of the control unit
and to the injector.
8. Connect the black hose for
supplementary air to the
corresponding output -
1.3
on the rear of the control
unit and to the injector.
9. Fit one end of the venting
hose onto the venting
connector (
11
) of the cover,
and place the other end in the opening of the booth.
Atmospheric pressure must be present in the powder hopper
during operation!
10. Connect the Mains cable to the socket
-
2.1
.
NOTICE
NOTICE
NOTICE
Mains connection
Aux
Gun
1.1 IN
5 ... 10 bar
73...145 PSI
1.4
2.2
2.3
2.1
1.3
1.2
1.5
Input voltage:
Input power:
Degree of protection:
Output:
Corresponding guns:
85 – 264 V
47 – 440 Hz
65 VA
IP 54
10 V 1,2 A
EasySelect
POWDER GUN CONTROL
TYPE EASYTRONIC