INSTALLATION CODES AND STANDARDS 

The hotplate must be installed in accordance with: 

In the United States of America: 

1.  State and local codes. 

2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but 

not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained 
from The American Gas Association Accredited Standards Committee Z223,  @ 400 
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 
1 Batterymarch Park Quincy, MA 02169-7471  

 

NOTE: In the Commonwealth of Massachusetts 

 

All gas appliances vented through a ventilation hood or exhaust system equipped with 
a damper or with a power means of exhaust shall comply with 248 CMR.  

3.  NFPA Standard # 96 

Vapor Removal from Cooking Equipment

, latest edition, available 

from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 

In Canada: 

1. Local codes. 

2.  CAN/CSA-B149.1 Natural Gas Installation (latest edition)   

3.  CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the 

Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3 

 

CASTER EQUIPPED APPLIANCES 

Hotplates mounted on stands with casters must use a flexible connector (not supplied) 
that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 
• CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-
Disconnect Devices for use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate 
means must be provided to limit movement of the hotplate without depending on the 
connector and the quick-disconnect device or its associated piping to limit hotplate 
movement. Attach the restraining device at the rear of the hotplate. If disconnection of 
the restraint is necessary, turn off the gas supply before disconnection. Reconnect the 
restraint prior to turning the gas supply on and return the hotplate to its installation 
position. 

If the Hotplate is installed on casters and is moved for any reason, it is recommended 
that it be re-leveled (see LEVELING). 

 
LEVELING 

If the hotplate is equipped with legs or is mounted on the optional stand equipped with 
legs, turn the feet at the bottom of the legs in or out to level the hotplate in the final 
installed location.  If the hotplate is mounted on the optional stand equipped with casters, 
position the hotplate on a level floor. 

VENTILATION HOOD 

The hotplate should be installed under a suitable ventilation hood. For safe operation and 
proper ventilation, keep the space between the hotplate and vent hood free from any 
obstructions. 

 

Summary of Contents for VHP212 ML-135AHP-12

Page 1: ...TURE USE FORM F 36955 04 07 INSTALLATION OPERATION MANUAL FOR Hotplates MODEL MLS VHP212 ML 135AHP 12 VHP424 ML 135AHP 24 VHP636 ML 135AHP 36 VHP848 ML 135AHP 48 www vulcanhart com MODELS MLS AHP212 ML 135AHP 12 AHP424 ML 135AHP 24 AHP636 ML 135AHP 36 AHP848 ML 135AHP 48 www wolfrange com AHP424 ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...e with the specifications on the rating plate riveted to the right side of the unit in the upper front corner If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer immediately LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the hotplate a...

Page 4: ... a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the hotplate without depending on the connector and the quick disconnect...

Page 5: ...d psig 3 45 kPa the appliance and its individual shutoff valve must be disconnected from the gas supply piping system When test pressures are psig 3 45 kPa or less the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the system WARNING PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE S...

Page 6: ...ng compound overnight In the morning rinse with hot water to remove any residues of cleaning compound Burner ports and burner rest should be thoroughly cleaned Venturi must be free from grease and lint When cleaning do not insert a pick into the burner port holes soap and water will normally do the job Heavy spattering or spill over may require cleaning with a mild oven cleaner After cleaning rins...

Reviews: