ITW Food Equipment Group VHP212 ML-135AHP-12 Installation & Operation Manual Download Page 3

 

- 3 - 

INSTALLATION, OPERATION AND CARE OF 

GAS COUNTERTOP HOTPLATE RANGE 

 

GENERAL 

 
Gas Countertop Hotplates are designed for commercial use only and feature fast, efficient 
gas heat.  Each burner is controlled by an adjustable gas valve. Cast grates and burners 
are easily removed for cleaning when cool. 
 

Model 

# of 

Burners 

BTU/hr Input Rating 

Standard & Step-Up 

BTU/hr Input Rating 

Half Hot-Top 

AHP212 / VHP212 

60,000 

45,000 (30,000 + 15,000) 

AHP424 / VHP424 

120,000 

90,000 (60,000 + 30,000) 

AHP636 / VHP636 

180,000 

135,000 (90,000 + 45,000) 

AHP848 / VHP848 

240,000 

180,000 (120,000 + 60,000) 

 
 

INSTALLATION 

UNPACKING 
 

Immediately after unpacking, check for possible shipping damage.  If the hotplate is found 
to be damaged, save the packaging material and contact the carrier within 15 days of 
delivery. 
 
Before installing, verify that the unit model and type of gas supply (natural gas or 
propane) agree with the specifications on the rating plate riveted to the right side of the 
unit in the upper front corner. If the supply and equipment requirements do not agree, do 
not proceed with the installation. Contact your dealer immediately. 

 

LOCATION 

The installation location must be kept free and clear of combustibles.  Do not obstruct the 
flow of combustion and ventilation air. DO NOT install the hotplate adjacent to open 
burners or fryers. 

Sufficient air should be allowed to enter the room to compensate for the amount of air 
removed by any ventilating system and for combustion of the gas burners.  Do not 
obstruct the air flow into and around the hotplate. Position the hotplate in its final 
location.  Check that there are sufficient clearances to service the hotplate and to make 
the required gas supply connection(s).  Provide 24" clearance at the front for cleaning, 
maintenance, service and proper operation.   

Minimum clearances to combustible construction are 6" to the back and 6" to the sides. 
Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides. 

 

Summary of Contents for VHP212 ML-135AHP-12

Page 1: ...TURE USE FORM F 36955 04 07 INSTALLATION OPERATION MANUAL FOR Hotplates MODEL MLS VHP212 ML 135AHP 12 VHP424 ML 135AHP 24 VHP636 ML 135AHP 36 VHP848 ML 135AHP 48 www vulcanhart com MODELS MLS AHP212 ML 135AHP 12 AHP424 ML 135AHP 24 AHP636 ML 135AHP 36 AHP848 ML 135AHP 48 www wolfrange com AHP424 ...

Page 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Page 3: ...e with the specifications on the rating plate riveted to the right side of the unit in the upper front corner If the supply and equipment requirements do not agree do not proceed with the installation Contact your dealer immediately LOCATION The installation location must be kept free and clear of combustibles Do not obstruct the flow of combustion and ventilation air DO NOT install the hotplate a...

Page 4: ... a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the hotplate without depending on the connector and the quick disconnect...

Page 5: ...d psig 3 45 kPa the appliance and its individual shutoff valve must be disconnected from the gas supply piping system When test pressures are psig 3 45 kPa or less the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the system WARNING PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE S...

Page 6: ...ng compound overnight In the morning rinse with hot water to remove any residues of cleaning compound Burner ports and burner rest should be thoroughly cleaned Venturi must be free from grease and lint When cleaning do not insert a pick into the burner port holes soap and water will normally do the job Heavy spattering or spill over may require cleaning with a mild oven cleaner After cleaning rins...